ScienceDirect® Home Skip Main Navigation Links
You have guest access to ScienceDirect. Find out more.
 
Home
Browse
My Settings
Alerts
Help
 Quick Search
 Search tips (Opens new window)
    Clear all fields    
advertisementadvertisement
Journal of Immunological Methods
Volume 184, Issue 1, 17 July 1995, Pages 39-51
 
Font Size: Decrease Font Size  Increase Font Size
 Abstract - selected
Purchase PDF (1557 K)

 
 
 
Related Articles in ScienceDirect
View More Related Articles
 
View Record in Scopus
 
doi:10.1016/0022-1759(95)00072-I    How to Cite or Link Using DOI (Opens New Window)
Copyright © 1995 Published by Elsevier Science B.V.

Research report

A novel assay for apoptosis Flow cytometric detection of phosphatidylserine expression on early apoptotic cells using fluorescein labelled Annexin V

István Vermesa, Corresponding Author Contact Information, Clemens Haanena, Helga Steffens-Nakkena and Chris Reutellingspergerb

a Department of Clinical Chemistry, Medical Spectrum Twente, P.O. Box 50.000, 7500 KA, Enschede, Netherlands b Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), State University Limburg, Maastricht, Netherlands

Received 3 October 1994; 
revised 2 December 1994; 
accepted 16 March 1995. ;
Available online 28 December 1999.

Purchase the full-text article



References and further reading may be available for this article. To view references and further reading you must purchase this article.

Abstract

In the early stages of apoptosis changes occur at the cell surface, which until now have remained difficult to recognize. One of these plasma membrane alterations is the translocation of phosphatidylserine (PS) from the inner side of the plasma membrane to the outer layer, by which PS becomes exposed at the external surface of the cell. Annexin V is a Ca2+ dependent phospholipid-binding protein with high affinity for PS. Hence this protein can be used as a sensitive probe for PS exposure upon the cell membrane. Translocation of PS to the external cell surface is not unique to apoptosis, but occurs also during cell necrosis. The difference between these two forms of cell death is that during the initial stages of apoptosis the cell membrane remains intact, while at the very moment that necrosis occurs the cell membrane looses its integrity and becomes leaky. Therefore the measurement of Annexin V binding to the cell surface as indicative for apoptosis has to be performed in conjunction with a dye exclusion test to establish integrity of the cell membrane.

This paper describes the results of such an assay, as obtained in cultured HSB-2 cells, rendered apoptotic by irradiation and in human lymphocytes, following dexamethasone treatment. Untreated and treated cells were evaluated for apoptosis by light microscopy, by measuring the amount of hypo-diploid cells using of DNA flow cytometry (FCM) and by DNA electrophoresis to establish whether or not DNA fragmentation had occurred. Annexin V binding was assessed using bivariate FCM, and cell staining was evaluated with fluorescein isothiocyanate (FITC)-labelled Annexin V (green fluorescence), simultaneously with dye exclusion of propidium iodide (PI) (negative for red fluorescence). The test described, discriminates intact cells (FITC/PI), apoptotic cells (FITC+/PI) and necrotic cells (FITC+/PI+). In comparison with existing traditional tests the Annexin V assay is sensitive and easy to perform. The Annexin V assay offers the possibility of detecting early phases of apoptosis before the loss of cell membrane integrity and permits measurements of the kinetics of apoptotic death in relation to the cell cycle. More extensive FCM will allow discrimination between different cell subpopulations, that may or may not be involved in the apoptotic process.

Author Keywords: Apoptosis; Annexin-V; Flow cytometry; Phosphatidylserine

Abbreviations: FCM, flow cytometry; PI, propidium iodide; FITC, fluorescein isothiocyanate; PS, phosphatidylserine

Article Outline

• References

 
Home
Browse
My Settings
Alerts
Help
Elsevier.com (Opens new window)
About ScienceDirect  |  Contact Us  |  Information for Advertisers  |  Terms & Conditions  |  Privacy Policy
Copyright © 2008 Elsevier B.V. All rights reserved. ScienceDirect® is a registered trademark of Elsevier B.V.