Continuous Electricity Generation at High Voltages and Currents Using Stacked Microbial Fuel Cells
Laboratory of Microbial Ecology and Technology (LabMET), Ghent University, Coupure Links 653, B-9000 Ghent, Belgium
Received for review December 20, 2005
Revised manuscript received March 14, 2006
Accepted March 16, 2006
Abstract:
Connecting several microbial fuel cell (MFC) units in
series or parallel can increase voltage and current; the
effect on the microbial electricity generation was as yet
unknown. Six individual continuous MFC units in a stacked
configuration produced a maximum hourly averaged
power output of 258 W m-3 using a hexacyanoferrate
cathode. The connection of the 6 MFC units in series and
parallel enabled an increase of the voltages (2.02 V at
228 W m-3) and the currents (255 mA at 248 W m-3), while
retaining high power outputs. During the connection in
series, the individual MFC voltages diverged due to microbial
limitations at increasing currents. With time, the initial
microbial community decreased in diversity and Gram-positive species became dominant. The shift of the microbial
community accompanied a tripling of the short time
power output of the individual MFCs from 73 W m-3 to
275 W m-3, a decrease of the mass transfer limitations and
a lowering of the MFC internal resistance from 6.5 ± 1.0
to 3.9 ± 0.5
. This study demonstrates a clear relation
between the electrochemical performance and the
microbial composition of MFCs and further substantiates
the potential to generate useful energy by means of MFCs.
Microbial fuel cells (MFCs) convert chemical energy to
electrical energy with the aid of microorganisms as biocatalysts (1). While being a marginal scientific issue for years,
they have, in recent years, been catching up with other
bioconversion concepts. New designs have evolved and the
operation has been switched from fed-batch to continuous
mode. (2, 3)
MFC voltages will remain limited; even neglecting the
internal losses, the voltage will never exceed a theoretical
open circuit voltage (OCV) of 1.14 V as determined by the
NADH (-0.32 V) and pure oxygen (+0.82 V) redox potentials
(8). The highest OCV thus far reported of 0.80 V (9) illustrates
this limitation. The maximum current on the other hand is
determined by the (i) MFC design which determines the
electrochemical losses (e.g., internal resistance) and convec
tive transport limitations (5, 10)
The use of series or parallel stacked MFCs are essential
to increase the voltages and currents produced by MFCs.
Connecting several fuel cells in series adds the voltages, while
one common current flows through all fuel cells (11). In case
several power sources are connected in parallel, the voltage
averages and the currents are added. Any desired current or
voltage could be obtained by combining the appropriate
number of series and parallel connected fuel cells or power
sources. However, electricity production in a MFC is a
microbial process and compliant to external conditions (10,
12)
In a MFC, the microorganisms are structured in a biofilm
and live in close contact with the electrode (4). An adaptation
or change of the microbial community will influence the
biofilm structure and its properties (13). The biofilm is part
of the electrolyte; hence, alterations of the composition or
structure of the biofilm might influence the electrochemical
characteristics and losses of the MFC. In a MFC the
electrochemical losses are categorized as (i) activation losses
which can be lowered by the microbial production of electron
shuttle or nanowires (5, 6, 14)
In this research, a stacked MFC consisting of six identical MFCs was used to (i) investigate the influence of the electrical circuit (series or parallel) on the power, voltage and current output of the overall stack and the MFC units in the stack and (ii) to monitor the evolution between the microbial community and electrochemical characteristic of the individual MFCs.
Microbial Fuel Cell Stack. The MFC stack consisted of six individual MFC units (Figure 1). They were constructed of 12 identical Perspex frames. In the frames, both a sample port and two inlets were constructed and 2 partitions were installed to obtain a complete flow through. A robust cation exchange membrane (Ultrex CMI7000, Membranes International Inc., U.S.) was used between the anode and cathode of each MFC unit. The six MFCs were separated by five rubber sheets. Both the anode and cathode electrodes consisted of graphite granules to collect the electrons (type00514, diameter between 1.5 and 5 mm, Le Carbone, Belgium) and a graphite rod (5 mm diameter, Morgan, Belgium) to connect to the external circuit. Prior to use, the granules were washed three times with water. The separated MFCs in the stack were electrically connected in series or parallel using copper wires connected to the electrodes. The total empty volume of one frame was 156 mL. After installation of 2 partitions and the graphite electrode, the void volume of one frame amounted to 60 mL. This volume was used in the calculations.
Operational Conditions. The MFCs were operated at a
room temperature of 22 ± 3
C. A sterile synthetic influent
containing 0.75 to 1.00 g L-1 sodium acetate (0.58-0.78 g
chemical oxygen demand (COD) L-1) prepared as previously
described (16) was continuously fed to the individual MFC
anodes by a peristaltic pump (Watson Marlow, Belgium) at
a flow rate of 7-21.1 mL h-1 corresponding to a hydraulic
retention time (HRT) of 8.86-2.86 h. Each MFC had a
recirculation loop with a flow rate of 106 mL h-1. Unless
stated otherwise, at day 104 a volumetric loading rate of 1.62
g COD L-1 d-1 was provided; 70 days later the volumetric
loading rate was increased to 2.17 g COD L-1 d-1.
The catholyte was prepared according to Park and Zeikus (7) and consisted of 50 mM K3Fe(CN)6 aqueous solution in a 100 mM KH2PO4 buffer (Merck, Belgium) adjusted to pH 7 with 1 M NaOH. The catholyte was recirculated through the cathodic matrix. The oxidation/reduction potential of the catholyte was controlled by either (i) a periodic renewal of the catholyte solution upon decolorization or (ii) a continuous electrochemical regeneration of the catholyte in an electrolysis cell.
Inoculation, Start-Up, and Experimental Timing. The anodic compartments of the MFC stack were inoculated with a mixture of anaerobic (Dendermonde, Belgium) and aerobic (Gent, Belgium) sludge. During start-up (day 0 to day 103), the stack was operated on several wastewaters: a domestic wastewater collected from a hospital (Ghent, Belgium) and two industrial organic streams: the influent and effluent of an anaerobic digester from a potato processing factory (Waregem, Belgium). Different operational conditions were imposed. Due to the qualitative variability of the influent and the limitations this represented regarding data processing and interpretation, the experiments were continued using a synthetic influent. This allowed us to increase the reproduc ibility. Three MFC duplicates with a common recirculation buffer vessel were installed at day 104. Starting from day 132, several analyses were conducted. The electrochemical analyses were made at regular intervals of approximately one month and were classified in three periods in time starting from the date of inoculation. The three periods in time are termed time 1 from day 132 to day 167, time 2 at day 175, and time 3 from day 200 to day 204.
Calculations of the Electrical Parameters. The electrodes
were connected in series, parallel, or individual over an
external resistance (R) (from 1.5 to 6000
). The potential (V)
of the six individual MFCs and the Coulombic efficiency was
measured according to (2).
To calculate power density, a void volume of 60 mL (individual MFC) or 360 mL (stacked MFC) was used. The short time power densities were calculated using the instant values obtained from the polarization curves. The hourly averaged power densities were calculated using the moving average of 60 voltage measurements during 1 h.
Electrochemical Analysis. The internal resistance was
determined using the current interrupt method (11, 15)
The anode potential was measured using an Ag/AgCl (197
mV versus SHE) reference electrode (BASi, Warwickshire,
United Kingdom).
Polarization curves were obtained by imposing a linear potential decrease followed by a linear voltage increase while measuring the current using a Bi-Stat potentiostat (Princeton Applied Research, Claix, France). The scan rate was 1 mV sec-1.
Microbial Community Analysis. Using a 10 mL syringe
with a 0.9 × 90 mm spinal needle (BD Needles, Erembodegem, Belgium) biomass was scraped off the anode granules
and subsequently sampled. Total DNA extraction (17) and16S
rRNA analysis for all Bacteria and PCR-DGGE analysis was
done as described previously (6, 18)
Nucleotide sequences for bands 1-8 and bands A-C have been deposited in GenBank database under accession number DQ315499-DQ315509. More information can be found on page S2 of the Supporting Information.
Stacked MFCs Provided Power at Enhanced Voltage and
Current. To increase the overall stack voltage or current, the
six individual MFCs (called MFC 1 to MFC 6) were respectively
connected in series or parallel. This resulted in an open circuit
voltage (OCV) of 0.67 V for the parallel connection and 4.16
V for the series connection. The series stack produced a short
circuit current (SCC) of 84.7 mA while the parallel stack
delivered a SCC of 425.0 mA. Both OCV and SCC were
approximately a factor of 6 higher than OCVs or SCC of the
individual MFCs (Table 1).The short time power output of
the series and parallel stack assessed at time 1 were similar
and equalled 107 W.m-3. At time 3, approximately 54 days
later, the maximum short time power densities had almost
tripled to 308 W m-3 (series) and 263 W m-3 (parallel) (Figure
2). The maximum short time power output of the series and
parallel stack were of the same order of magnitude. However,
the series stack produced this power at a higher voltage of
2279 mV (49 mA), while the parallel stack delivered an
increased current of 269 mA at 354 mV (Figure 2). Based
upon the polarization curves, the optimal external resistance
was 49.1
(series) and 1.3
(parallel) at time 3 (Table 1
).
Using the optimal resistances, the hourly averaged maximum
power outputs of the series and parallel stack were assessed
and amounted to respectively 228 W m-3 (at 2.02 V and 41.0
mA) and 248 W m-3 (at 0.35 V and 255 mA). The Coulombic
efficiency was 12.4%, for the series connection and 77.8% for
the parallel connection, both based on a volumetric loading
of 5.6 kg COD.m-3.d-1. The high power outputs obtained
during short time polarization experiments could be maintained for at least 1 h under stacked conditions i.e., at
enhanced voltage or current.
Individual MFC Voltages Influenced by Series Connec
tion at Higher Currents. At time 1 the series circuit was
closed using a variable external resistance (6000-15
). The
individual MFCs voltages and the overall stack voltage were
monitored at several currents during 30 min periods (Figure
3). At external resistances of 6000-510
, corresponding with
low currents of 0.7-7.4 mA, low variances between the
voltages of the individual MFCs were observed. However,
starting from 360
(10.1 mA) the individual MFC voltages
started to diverge. This resulted in an unequal distribution
of the individual MFCs voltages. The voltage differences
between the MFCs increased to as much as 0.99 V. The latter
was even accompanied with negative voltages or a reverse
of polarity of tree individual MFCs (MFC 3 to MFC 6). The
voltages of MFC 4 to MFC 6 increased and returned to their
normal state when the series stack was separated in individual
MFCs. Despite the increasing variance between the MFC
voltages, the total stack voltage followed a linear ohmic
decrease with increasing current until 90
(27.7 mA) when
voltage dropped faster.
Mutual and Time-Related Electrochemical Differences
of the Individual MFCs. Large differences between the
performance of the stack MFC at time 1 and time 3 could be
observed. In addition, differences in power output between
the individual MFCs 1-6 were noticed. These significant
differences were examined using basic electrochemical
analysis, polarization curves, and a molecular analysis. Table
1 gives an overview of the electrochemical parameters of the
individual MFCs and both the series and parallel stack. At
time 1, the average internal resistance (Rint) of the six MFCs
was 6.5 ± 1.0
. Remarkably, at time 3 the average Rint was
lowered to 3.9 ± 0.5
. In contrast to the Rint, the OCVs of
the six MFCs were similar and averaged 0.69 ± 0.01 V (time
1) and 0.67 ± 0.01 V (time 3). The SCC produced by the six
MFCs at time 1 showed large differences and were 2 times
lower than currents at time 3 which were in addition very
equal.
To further elucidate the evolution of the electrochemical response of the six MFCs, polarization curves were recorded at time 1, 2, and 3 (Figure 4). Three distinct polarization graphs were obtained for MFC 2, MFC 4, and MFC 6 (their respective duplicates MFC 1, 3, and 5 were analogous). At time 1, the voltage curves of MFC 4 and 6 decreased linearly. However, the voltage curve of MFC 2 showed a return at higher currents, despite its better performance (Figure 4). In addition, there was a notable difference in the maximum power density of MFC 6 (73 W m-3 at 12.2 mA) and of MFC 2 (167 W m-3 at 30.3 mA). At time 2, the power output of all MFCs had increased, resulting in maximum power densities of 144 W m-3 at 25.8 mA (MFC 6) and 200 W m-3 at 36.6 mA (MFC 2). Despite the overall increase, the voltage and power density curves of all the MFCs bended back starting at currents from 35 mA (MFC 6) to 40 mA (MFC 2), indicating limiting processes in all MFCs. At time 3, power output had further increased to levels of 265 W m-3 at 49.0 mA (MFC 4) and 281W m-3 at 51.1 mA (MFC 2) and strikingly, no return of the voltage curves of the six MFCs could be observed. Moreover both shape and height of the symmetrical power density curves were very identical and power outputs reached high levels.
Evolution of the Microbial Community in the Individual MFCs. The Denaturing Gradient Gel Electrophoresis (DGGE) patterns of the individual MFCs at time 1 and 3 were used to monitor changes in the microbial community (Figure 5). Cluster analysis of the community at time 1, grouped the three MFC duplicates. The Pearson correlation for each duplicate was at least 80%. However, a low similarity between the three duplicates existed. The DGGE profile of the MFCs at time 3 revealed major shifts in the band pattern. Cluster analysis indicated a strong resemblance of the microbial composition between the six individual MFCs at time 3 (Pearson correlation over 97%). The microbial composition of time 3 and time 1 showed no correlation. To identify the most abundant ribotypes at time 1, bands were excised and sequenced. The major part of the identified species belonged to the phylum of the Proteobacteria. The other identified species were members of the Firmicutes and the Actinobacteria. For time 3, the 16S rRNA genes of one MFC were cloned and 40 clones were screened by DGGE. Clones representing bands A, B, and C accounted for, respectively, 13, 38, and 8% of all clones sequences (Figure 5). Sequencing showed that the mutual differences of the representative clones of the three bands were low (>98% similarity) and that all the clones were similar to Brevibacillus agri (99% similarity), belonging to the Firmicutes.
Microbial Community and MFC Design Sustained High
Performance. The operation of the three best performing
individual MFCs was evaluated in order (i) to compare with
the stack performance and (ii) to asses long term power
output. Using the averaged optimal external resistances for
the individual MFCs at time 3 resulted in a maximum hourly
averaged power density of 189 ± 6 W m-3 (n = 3) (7.2
) at
a Coulombic efficiency of 76.2 ± 1.2% (Bv = 6.6 g COD L-1
day-1). At an external resistance of 10
, power output was
higher and reached 258 ± 3 W m-3 (n = 3) at a Coulombic
efficiency of 71.6 ± 0.4% or a substrate to electricity
conversion of 4.7 ± 0.1 g COD L-1 d-1. After 5 h, power had
lowered to 146 ± 2 W m-3, but remained roughly constant
at this level for 11 more hours.
The Stack Provided High Power Densities at Enhanced
Voltages and Currents. This paper demonstrates the use of
stacked MFCs (both in series and parallel) to produce high
power densities at enhanced voltages or currents. The
maximum power outputs were unaffected by the series or
parallel connection although individual MFCs could produce
a higher hourly averaged power output. The reported hourly
averaged power outputs were the highest thus far observed
in continuous systems. They were almost three times higher
compared to both the previous reported power densities for
hexacyanoferrate and platinum coated cathode systems (2,
19)
A large difference between the Coulombic efficiency of the series and parallel connected stack was noted. Since both systems were operated at the same volumetric loading rate, this difference was caused by a 6 times lower current production of the series connection compared to the current production of the parallel connection. Thus, the connection of MFCs in series will not allow high current densities. However, if rapid COD removal and hence high current densities are required, the use of a individual MFCs or MFCs connected in parallel is appropriate.
By combining the individual polarization curves, one can deduce that the MFCs connected in series and parallel, worked, respectively, at an average current and voltage determined by the performance of the individual MFCs. As a consequence, stacked MFCs will not deliver higher power densities than the individual MFCs. Yet, they create the possibility to produce an averaged power at more practical voltages and currents.
During the series connection, large differences of the individual MFC voltages could be noted when currents increased. Remarkably, the voltage of some MFCs in the stack even reversed polarity. This phenomenon is called cell reversal and also applies to proton exchange membrane fuel cells. Drawing excessive current from a fuel cell at a rate higher than its fuel delivery supports, leads to an increase of the anode potential and subsequent cell reversal. Fuel starvation, i.e., an inadequate supply of fuel, is a major cause of cell reversal and can occur during a sudden change of fuel demand such as during start-up or a change of the load (20). During our experiments, fuel delivery was adequate and the produced currents did not exceed the substrate loading rate. However, a rise of the anode potential (data not shown) and a subsequent cell reversal (Figure 3) could be observed. The MFCs which suffered cell reversal at time 1 produced a maximum current lower than the highest current during the series connection. This indicates that an excessive current might have been drawn from these MFCs during the series connection. The maximum current production is determined by the catalytic properties of the microbial consortium which influences both the rate and efficiency of the substrate to electric current conversion. Hence, since substrate delivery for all MFCs was adequate, the cell reversal was most likely a consequence of the limiting catalytic substrate conversion properties of some microbial consortia. This indicated that the external circuit had an influence on the microbial electricity production. However, a normal functioning of the MFCs was retrieved when disconnecting the stack to single MFCs.
Gram-Positive Species Dominate Limited Anodophilic
Consortium. Major differences between the microbial com
munity at time 1 and time 3 were observed. The microbial
communities of the MFCs shifted from a mixed and diverse
population to one very similar consortium for the distin
guished MFCs, dominated by a limited amount of species.
At time 1, most sequenced species were members of the
Proteobacteria. All Proteobacteria are Gram-negative and are
endowed with metabolic diversity (8). Several authors have
found members of the Proteobacteria in MFCs (21, 22)
Most strikingly, at time 3 when the performance was high, the microbial community was dominated by Brevibacillus agri a member of the Gram-positive Bacilli class. Two papers reported Gram-positive isolates respectively related to Enterococcus gallinarum (6) and Clostridium butyricum (24). At time 3, a previously described Pseudomonas species was also present but did not become dominant (6). However, the Pseudomonas species might have supported the electricity generation by producing mediators which are known to potentially enhance the electron transfer of other bacterial species (5). This finding urges the need to investigate the possible electron transfer differences between Gram-positive and Gram-negative species.
A Change of the Microbial Community Accompanied a
Decrease of the Internal Resistance. The current interrupt
method, a straightforward but advantageous method to
elucidate the internal resistance (Rint) of the MFCs in the
stack, indicated that the Rint values of the MFCs decreased
over time. The measured Rint values were low compared to
previous reports (25-29)
Evolution of the Polarization Curves of the Individual
MFCs. Polarization curves provide several insights. The height
of the polarization curves is related to overall performance
of the MFC while the shape is related to the presence of the
different polarizations or losses (11, 15)
A Microbial and Electrochemical Relation. This is the first report that relates the evolution of the electrochemical and microbial features of MFCs. Indeed, the shift from six different microbial communities to one limited consortium accompanied a decrease of the Rint, a shift in the polarization curves, and an overall increase of the power output. These findings favor the use of electrochemical techniques to elucidate the performance of both the microbial fuel cell design and the microbial community.
Practical Implications and Future Research. The good performance of stacked MFCs is a promising finding since for practical implementation high voltages and currents are required. However, if more MFCs are connected or higher current densities are achieved, the use of bipolar plates will be needed. Bipolar plates are placed between the anode and cathode of two adjacent MFCs and provide electrical conduction and mass separation (11). In this research, bipolar plates have been omitted to preserve maximum flexibility to change the external electrical connection. Furthermore, there is a need for cost-effective and robust cathodes. These major issues need to be dealt with in future designs but nevertheless the presented data underline the energy recovery potential of the MFC.
This research was funded by a Ph.D grant (IWT grant n
41294) of the Institute for the Promotion of Innovation
through Science and Technology in Flanders (IWT-Vlaanderen) and a fund of the Research Foundation-Flanders
(FWO project G.0172.05). We thank Petra Vandamme for her
help with the molecular analyses. The useful comments of
Tom Defoirdt were highly appreciated.
The basic electrochemical characteristic of the individual MFCs, the procedure for the microbial community analysis, and the composition of the microbial community. This material is available free of charge via the Internet at http://pubs.acs.org.
* Corresponding author phone: +32 (0)9 264 59 76; fax: +32 (0)9 264 62 48; e-mail: Willy.Verstraete@UGent.be.
1. Allen, R. M.; Bennetto, H. P. Microbial fuel-cells-electricity
production from carbohydrates. Appl. Biochem. Biotechnol.
1993, 39, 27-40.
2. Rabaey, K.; Clauwaert, P.; Aelterman, P.; Verstraete, W. Tubular
microbial fuel cells for efficient electricity generation. Environ.
Sci. Technol. 2005, 39, 8077.
3. Liu, H.; Ramnarayanan, R.; Logan, B. E. Production of electricity
during wastewater treatment using a single chamber microbial
fuel cell. Environ. Sci. Technol. 2004, 38, 2281-2285.
4. Bond, D. R.; Lovley, D. R. Electricity production by Geobacter
sulfurreducens attached to electrodes. Appl. Environ. Microbiol.
2003, 69, 1548-1555.
5. Rabaey, K.; Boon, N.; Höfte, M.; Verstraete, W. Microbial
phenazine production enhances electron transfer in biofuel cells.
Environ. Sci. Technol. 2005, 39, 3401-3408.
6. Rabaey, K.; Boon, N.; Siciliano, S. D.; Verhaege, M.; Verstraete,
W. Biofuel cells select for microbial consortia that self-mediate
electron transfer. Appl. Environ. Microbiol. 2004, 70, 5373-5382.
7. Park, D. H.; Zeikus, J. G. Improved fuel cell and electrode designs
for producing electricity from microbial degradation. Biotechnol.
Bioeng. 2003, 81, 348-355.
8. Madigan, M. T.; Martinko, J. M.; Parker, J. Brock Biology of Microorganisms; Prentice Hall: Upper Saddle River, NJ, 2000.
9. Liu, H.; Cheng, S. A.; Logan, B. E. Production of electricity from
acetate or butyrate using a single-chamber microbial fuel cell.
Environ. Sci. Technol. 2005, 39, 658-662.
10. Moon, H.; Chang, I. S.; Jang, J. K.; Kim, B. H. Residence time
distribution in microbial fuel cell and its influence on COD
removal with electricity generation. Biochem. Eng. J. 2005, 27,
59-65.
11. Larminie, J.; Dicks, A. Fuel Cell Systems Explained; John Wiley & Sons: Chichester, UK, 2000.
12. Liu, H.; Cheng, S. A.; Logan, B. E. Power generation in fed-batch
microbial fuel cells as a function of ionic strength, temperature,
and reactor configuration. Environ. Sci. Technol. 2005, 39, 5488-5493.
13. Sutherland, I. W. The biofilm matrix-an immobilized but
dynamic microbial environment. Trends Microbiol. 2001, 9, 222-227.
14. Reguera, G.; McCarthy, K. D.; Mehta, T.; Nicoll, J. S.; Tuominen,
M. T.; Lovley, D. R. Extracellular electron transfer via microbial
nanowires. Nature 2005, 435, 1098-1101.
15. Hoogers, G. Fuel Cell Components and Their Impact on Performance. In Fuel Cell Technology Handbook; Hoogers, G., Ed.; CRC: Boca Raton, FL, 2003.
16. Rabaey, K.; Ossieur, W.; Verhaege, M.; Verstraete, W. Continuous
microbial fuel cells convert carbohydrates to electricity. Water
Sci. Technol. 2005, 52, 515-523.
17. Boon, N.; Goris, J.; De Vos, P.; Verstraete, W.; Top, E. M.
Bioaugmentation of activated sludge by an indigenous 3-chloroaniline degrading Comamonas testosteroni strain, I2gfp. Appl.
Environ. Microbiol. 2000, 66, 2906-2913.
18. Boon, N.; De Windt, W.; Verstraete, W.; Top, E. M. Evaluation
of nested PCR-DGGE (denaturing gradient gel electrophoresis)
with group-specific 16S rRNA primers for the analysis of bacterial
communities from different wastewater treatment plants. FEMS
Microbiol. Ecol. 2002, 39, 101-112.
19. Moon, H.; Chang, I. S.; Kim, B. H. Continuous electricity
production from artificial wastewater using a mediator-less
microbial fuel cell. Bioresour. Technol. 2006, 97, 621-627.
20. Taniguchi, A.; Akita, T.; Yasuda, K.; Miyazaki, Y. Analysis of
electrocatalyst degradation in PEMFC caused by cell reversal
during fuel starvation. J. Power Sources 2004, 130, 42-49.
21. Phung, N. T.; Lee, J.; Kang, K. H.; Chang, I. S.; Gadd, G. M.; Kim,
B. H. Analysis of microbial diversity in oligotrophic microbial
fuel cells using 16S rDNA sequences. FEMS Microbiol. Lett. 2004,
233, 77-82.
22. Kim, B. H.; Park, H. S.; Kim, H. J.; Kim, G. T.; Chang, I. S.; Lee,
J.; Phung, N. T. Enrichment of microbial community generating
electricity using a fuel-cell-type electrochemical cell. Appl.
Microbiol. Biotechnol. 2004, 63, 672-681.
23. Kim, H. J.; Park, H. S.; Hyun, M. S.; Chang, I. S.; Kim, M.; Kim,
B. H. A mediator-less microbial fuel cell using a metal reducing
bacterium, Shewanella putrefaciens. Enzyme Microb. Technol.
2002, 30, 145-152.
24. Park, H. S.; Kim, B. H.; Kim, H. S.; Kim, H. J.; Kim, G. T.; Kim,
M.; Chang, I. S.; Park, Y. K.; Chang, H. I. A novel electrochemically
active and Fe(III)-reducing bacterium phylogenetically related
to Clostridium butyricum isolated from a microbial fuel cell.
Anaerobe 2001, 7, 297-306.
25. He, Z.; Minteer, S. D.; Angenent, L. T. Electricity generation
from artificial wastewater using an upflow microbial fuel cell.
Environ. Sci. Technol. 2005, 39, 5262-5267.
26. Jang, J. K.; Pham, T. H.; Chang, I. S.; Kang, K. H.; Moon, H.; Cho,
K. S.; Kim, B. H. Construction and operation of a novel mediator-
and membrane-less microbial fuel cell. Process Biochem. 2004,
39, 1007-1012.
27. Oh, S. E.; Min, B.; Logan, B. E. Cathode performance as a factor
in electricity generation in microbial fuel cells. Environ. Sci.
Technol. 2004, 38, 4900-4904.
28. Ieropoulos, I. A.; Greenman, J.; Melhuish, C.; Hart, J. Comparative
study of three types of microbial fuel cell. Enzyme Microb.
Technol. 2005, 37, 238-245.
29. Min, B.; Cheng, S.; Logan, B. E. Electricity generation using
membrane and salt bridge microbial fuel cells. Water Res. 2005,
39, 1675-1686.
30. Bond, D. R.; Lovley, D. R. Evidence for involvement of an electron
shuttle in electricity generation by Geothrix fermentans. Appl.
Environ. Microbiol. 2005, 71, 2186-2189.
|
time 1 |
time 3 |
|||||||
|
|
Rint
( |
Ropt
( |
SCC (mA) |
OCV (mV) |
Rint
( |
Ropt
( |
SCC (mA) |
OCV (mV) |
|
average MFCs |
6.5 ± 1.0 |
19.2 ± 9.0 |
31.4 ± 7.8 |
693± 1 |
3.9 ± 0.5 |
7.2 ± 1.0 |
74.7 ± 5.8 |
671± 7 |
|
series |
ndb |
113.7 |
25.5 |
4158 |
ndb |
49.1 |
84.7 |
ndb |
|
parallel |
ndb |
2.1 |
177.1 |
668 |
ndb |
1.3 |
425.0 |
ndb |
a The data of the 6 individual MFCs can be found in table S1 of the Supporting Information.b nd: not determined.