Electrosonic spray ionization (ESSI), a variant on electrospray ionization (ESI), employs a traditional micro ESI source with supersonic nebulizing gas. The high linear velocity of the nebulizing gas provides efficient pneumatic spraying of the charged liquid sample. The variable electrostatic potential can be tuned to allow efficient and gentle ionization. This ionization method is successfully applied to aqueous solutions of various proteins at neutral pH, and its performance is compared to that of the nanospray and micro ESI techniques. Evidence for efficient desolvation during ESSI is provided by the fact that the peak widths for various multiply charged protein ions are an order of magnitude narrower than those for nanospray. Narrow charge-state distributions compared to other ESI techniques are observed also; for most of the proteins studied, more than 90% of the protein ions can be accumulated in one charge state using ESSI when optimizing conditions. The fact that the abundant charge state is normally as low or lower than that recorded by ESI or nanospray indicates that folded protein ions are generated. The sensitivity of the ionization technique to high salt concentrations is comparable to that of nanospray, but ESSI is considerably less sensitive to high concentrations of organic additives such as glycerol or 2-amino-2-(hydroxymethyl)-1,3-propanediol (Tris base). Noncovalent complexes are observed in the case of myoglobin, protein kinase A/ATP complex, and other proteins. The extent of dissociation of protein ions in ESSI is comparable to or even smaller than that in the case of nanospray, emphasizing the gentle nature of the method. The unique features of ESSI are ascribed to very efficient spraying and the low internal energy supplied to the ions. Evidence is provided that the method is capable of generating fully desolvated protein ions at atmospheric pressure. This allows the technique to be used for the study of ion−molecule reactions at atmospheric pressure and examples of this are shown.
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 22 ACS Journal articles (5 most recent appear below).

Alkali Metal Cation-Induced Destabilization of Gas-Phase Protein–Ligand Complexes: Consequences and Prevention
Jonathan T. S. Hopper and Neil J. OldhamAnalytical Chemistry2011 83 (19), 7472-7479Alkali Metal Cation-Induced Destabilization of Gas-Phase Protein–Ligand Complexes: Consequences and Prevention
Jonathan T. S. Hopper and Neil J. OldhamAnalytical Chemistry2011 83 (19), 7472-7479Electrospray ionization, now a well established technique for studying noncovalent protein–ligand interactions, is prone to production of alkali metal adducts. Here it is shown that this adduction significantly destabilizes the interactions between two ...

Ambient Ion Soft Landing
Abraham K. Badu-Tawiah, Chunping Wu, and R. Graham CooksAnalytical Chemistry2011 83 (7), 2648-2654Ambient Ion Soft Landing
Abraham K. Badu-Tawiah, Chunping Wu, and R. Graham CooksAnalytical Chemistry2011 83 (7), 2648-2654Ambient ion soft landing, a process in which polyatomic ions are deposited from air onto a surface at a specified location under atmospheric pressure, is described. Ions generated by electrospray ionization are passed pneumatically through a heated metal ...

Online Mass Spectrometric Analysis of Proteins/Peptides Following Electrolytic Cleavage of Disulfide Bonds
Yun Zhang, Howard D. Dewald, and Hao ChenJournal of Proteome Research2011 10 (3), 1293-1304Online Mass Spectrometric Analysis of Proteins/Peptides Following Electrolytic Cleavage of Disulfide Bonds
Yun Zhang, Howard D. Dewald, and Hao ChenJournal of Proteome Research2011 10 (3), 1293-1304The disulfide bond bridge is an important post-translational modification for proteins. This study presents a structural analysis of biologically active peptides and proteins containing disulfide bonds using electrochemistry (EC) online combined with ...

Surface Sampling by Spray-Desorption Followed by Collection for Chemical Analysis
Andre R. Venter, Afrand Kamali, Shashank Jain and Semere BairuAnalytical Chemistry2010 82 (5), 1674-1679Surface Sampling by Spray-Desorption Followed by Collection for Chemical Analysis
Andre R. Venter, Afrand Kamali, Shashank Jain and Semere BairuAnalytical Chemistry2010 82 (5), 1674-1679Desorption electrospray ionization (DESI) directly analyzes soluble chemical components present on surfaces when a pneumatically assisted electrospray is directed at the sample. Here we demonstrate that the same spray desorption mechanism that operates in ...

Online Coupling of Electrochemical Reactions with Liquid Sample Desorption Electrospray Ionization-Mass Spectrometry
Jiwen Li, Howard D. Dewald and Hao ChenAnalytical Chemistry2009 81 (23), 9716-9722Online Coupling of Electrochemical Reactions with Liquid Sample Desorption Electrospray Ionization-Mass Spectrometry
Jiwen Li, Howard D. Dewald and Hao ChenAnalytical Chemistry2009 81 (23), 9716-9722The combination of electrochemistry (EC) and mass spectrometry (MS) is a powerful analytical tool to study redox reactions. This work reports the online coupling of a thin-layer electrochemical flow cell with liquid sample desorption electrospray ...
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Published In Issue July 15, 2004
- Received for review January 26, 2004. Accepted April 14, 2004.
Cart


ACS
Network