Accelerated Article
Desorption Electrospray Ionization of Explosives on Surfaces: Sensitivity and Selectivity Enhancement by Reactive Desorption Electrospray Ionization
Purchase the full-text
- PDF/HTML,
figures/images,
references and tables,
(where available)
Abstract
Desorption electrospray ionization (DESI), an ambient mass spectrometry technique, is used for trace detection of the explosives trinitrohexahydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), 2,4,6-trinitrotoluene (TNT), Pentaerythritol tetranitrate (PETN), and their plastic compositions (Composition C-4, Semtex-H, Detasheet) directly from a wide variety of surfaces (metal, plastic, paper, polymer) without sample preparation or pretreatment. Analysis of the explosives is performed under ambient conditions from virtually any surface in very short times (<5 s) including confirmatory tandem mass spectrometry (MS/MS) experiments, while retaining the sensitivity and specificity that mass spectrometry offers. Increased selectivity is obtained both by MS/MS and by performing additional experiments in which additives are included in the spray solvent. These reactive DESI experiments (reactions accompanying desorption) produce such ions as the chloride and trifluoroacetate adducts of RDX and HMX or the Meisenheimer complex of TNT. Desorption atmospheric pressure chemical ionization, a variant of DESI that uses gas-phase ions generated by atmospheric pressure corona discharges of toluene or other organic compounds, provides evidence for a heterogeneous-phase (gaseous ion/absorbed analyte) charge-transfer mechanism of DESI ionization in the case of explosives. Plastic explosives on surfaces were analyzed directly as fingerprints, without sample preparation, to test DESI as a possible method for in situ detection of explosives-contaminated surfaces. DESI also allowed detection of explosives in complex matrixes, including lubricants, household cleaners, vinegar, and diesel fuel. Absolute limits of detection for the neat explosives were subnanogram in all cases and subpicogram in the case of TNT. The DESI response was linear over 3 orders of magnitude for TNT. Quantification of RDX on paper gave a precision (RSD) of 2.3%. Pure water could be used as the spray solution for DESI, and it showed ionization efficiencies for RDX in the negative ion mode similar to that given by methanol/water. DESI represents a simple and rapid way to detect explosives in situ with high sensitivity and specificity and is especially useful when they are present in complex mixtures or in trace amounts on ordinary environmental surfaces.
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 31 ACS Journal articles (5 most recent appear below).

Determination of Inorganic Improvised Explosive Device Signatures Using Laser Electrospray Mass Spectrometry Detection with Offline Classification
Paul M. Flanigan, IV, John J. Brady, Elizabeth J. Judge, and Robert J. LevisAnalytical Chemistry2011 Article ASAPDetermination of Inorganic Improvised Explosive Device Signatures Using Laser Electrospray Mass Spectrometry Detection with Offline Classification
Paul M. Flanigan, IV, John J. Brady, Elizabeth J. Judge, and Robert J. LevisAnalytical Chemistry2011 Article ASAPThe mass spectral detection of low vapor pressure, inorganic-based explosive signatures including ammonium nitrate, chlorate, perchlorate, sugar, and the constituents contained within black powder are reported using laser electrospray mass spectrometry. ...

Ionization-Enhanced Decomposition of 2,4,6-Trinitrotoluene (TNT) Molecules
Bin Wang, David Wright, David Cliffel, Richard Haglund, and Sokrates T. PantelidesThe Journal of Physical Chemistry A2011 Article ASAPIonization-Enhanced Decomposition of 2,4,6-Trinitrotoluene (TNT) Molecules
Bin Wang, David Wright, David Cliffel, Richard Haglund, and Sokrates T. PantelidesThe Journal of Physical Chemistry A2011 Article ASAPThe unimolecular decomposition reaction of TNT can in principle be used to design ways to either detect or remove TNT from the environment. Here, we report the results of a density functional theory study of possible ways to lower the reaction barrier for ...

Interfacing Capillary-Based Separations to Mass Spectrometry Using Desorption Electrospray Ionization
Griffin K. Barbula, Samir Safi, Konstantin Chingin, Richard H. Perry, and Richard N. ZareAnalytical Chemistry2011 83 (6), 1955-1959Interfacing Capillary-Based Separations to Mass Spectrometry Using Desorption Electrospray Ionization
Griffin K. Barbula, Samir Safi, Konstantin Chingin, Richard H. Perry, and Richard N. ZareAnalytical Chemistry2011 83 (6), 1955-1959The powerful hybrid analysis method of capillary-based separations followed by mass spectrometric analysis gives substantial chemical identity and structural information. It is usually carried out using electrospray ionization. However, the salts and ...

Detection of Explosives and Related Compounds by Low-Temperature Plasma Ambient Ionization Mass Spectrometry
Juan F. Garcia-Reyes, Jason D. Harper, Gary A. Salazar, Nicholas A. Charipar, Zheng Ouyang, and R. Graham CooksAnalytical Chemistry2011 83 (3), 1084-1092Detection of Explosives and Related Compounds by Low-Temperature Plasma Ambient Ionization Mass Spectrometry
Juan F. Garcia-Reyes, Jason D. Harper, Gary A. Salazar, Nicholas A. Charipar, Zheng Ouyang, and R. Graham CooksAnalytical Chemistry2011 83 (3), 1084-1092Detection of explosives is important for public safety. A recently developed low-temperature plasma (LTP) probe for desorption and ionization of samples in the ambient environment (Anal. Chem. 2008, 80, 9097) is applied in a comprehensive evaluation of ...

Characterization of Composition C4 Explosives using Time-of-Flight Secondary Ion Mass Spectrometry and X-ray Photoelectron Spectroscopy
Christine M. Mahoney, Albert J. Fahey, Kristen L. Steffens and Bruce A. Benner, Jr., Richard T. LareauAnalytical Chemistry2010 82 (17), 7237-7248Characterization of Composition C4 Explosives using Time-of-Flight Secondary Ion Mass Spectrometry and X-ray Photoelectron Spectroscopy
Christine M. Mahoney, Albert J. Fahey, Kristen L. Steffens and Bruce A. Benner, Jr., Richard T. LareauAnalytical Chemistry2010 82 (17), 7237-7248The application of surface analytical techniques such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS) is explored as a means of differentiating between composition C4 plastic explosives (C-4). Three ...
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Published In Issue November 01, 2005
- Received for review June 5, 2005. Accepted August 20, 2005.
Cart

ACS
Network






