Article
Dependence of Effective Peak Capacity in Comprehensive Two-Dimensional Separations on the Distribution of Peak Capacity between the Two Dimensions
Purchase the full-text
- PDF/HTML,
figures/images,
references and tables,
(where available)
Abstract
One of the basic tenets of comprehensive two-dimensional chromatography is that the total peak capacity is simply the product of the first- and second-dimension peak capacities. As formulated, the total peak capacity does not depend on the relative values of the individual dimensions but only on the product of the two. This concept is tested here for the experimentally realistic situation wherein the first-dimension separation is undersampled. We first propose that a relationship exists between the number of observed peaks in a two-dimensional separation and the effective peak capacity. We then show here for a range of reasonable total peak capacities (500−4000) and various contributions of peak capacity in each dimension (10−150) that the number of observed peaks is only slightly dependent on the relative contributions over a reasonable and realistic range in sampling times (equal to the first-dimension peak standard deviation, multiplied by 0.2−16). Most of this work was carried out under the assumption of totally uncorrelated retention times. For uncorrelated separations, the small deviations from the product rule are due to the “edge effect” of statistical overlap theory and a recently introduced factor that corrects for the broadening of first-dimension peaks by undersampling them. They predict that relatively more peaks will be observed when the ratio of the first- to the second-dimension peak capacity is much less than unity. Additional complications are observed when first- and second-dimension retention times show some correlation, but again the effects are small. In both cases, deviations from the product rule are measured by the relative standard deviations of the number of observed peaks, which are typically 10 or less. Thus, although the basic tenet of two-dimensional chromatography is not exact when the first dimension is undersampled, the deviations from the product rule are sufficiently small as to be unimportant in practical work. Our results show that practitioners have a high degree of flexibility in designing and optimizing experimental comprehensive two-dimensional separations.
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 3 ACS Journal articles (3 most recent appear below).

Online Comprehensive RPLC × RPLC with Mass Spectrometry Detection for the Analysis of Proteome Samples
Paola Donato, Francesco Cacciola, Eduardo Sommella, Chiara Fanali, Laura Dugo, Marina Dachà, Pietro Campiglia, Ettore Novellino, Paola Dugo, and Luigi MondelloAnalytical Chemistry2011 83 (7), 2485-2491Online Comprehensive RPLC × RPLC with Mass Spectrometry Detection for the Analysis of Proteome Samples
Paola Donato, Francesco Cacciola, Eduardo Sommella, Chiara Fanali, Laura Dugo, Marina Dachà, Pietro Campiglia, Ettore Novellino, Paola Dugo, and Luigi MondelloAnalytical Chemistry2011 83 (7), 2485-2491LC-MS-based shotgun proteomics relies both on the power of the separation techniques and the sensitivity of detection methods. As a viable alternative to classical approaches in this field, we developed a fully automated, comprehensive 2D LC system, in ...

Effective Saturation: A More Informative Metric for Comparing Peak Separation in One- and Two-Dimensional Separations
Joe M. Davis, Peter W. CarrAnalytical Chemistry2009 81 (3), 1198-1207Effective Saturation: A More Informative Metric for Comparing Peak Separation in One- and Two-Dimensional Separations
Joe M. Davis, Peter W. CarrAnalytical Chemistry2009 81 (3), 1198-1207A theoretical comparison is made of the numbers of observed peaks in one-dimensional (1D) and two-dimensional (2D) separations having the same peak capacity, as calculated from the traditional metric of resolution. The shortcoming of the average minimum ...

Equation for Peak Capacity Estimation in Two-Dimensional Liquid Chromatography
Xiaoping Li, Dwight R. Stoll and Peter W. CarrAnalytical Chemistry2009 81 (2), 845-850Equation for Peak Capacity Estimation in Two-Dimensional Liquid Chromatography
Xiaoping Li, Dwight R. Stoll and Peter W. CarrAnalytical Chemistry2009 81 (2), 845-850Two-dimensional liquid chromatography (2DLC) is a very powerful way to greatly increase the resolving power and overall peak capacity of liquid chromatography. The traditional “product rule” for peak capacity usually overestimates the true resolving power ...
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Published In Issue November 01, 2008
- Article ASAPOctober 08, 2008
- Received: May 6, 2008
Accepted: August 12, 2008
Cart

ACS
Network