Article
Effect of Pressure, Particle Size, and Time on Optimizing Performance in Liquid Chromatography
Purchase the full-text
- PDF/HTML,
figures/images,
references and tables,
(where available)
Current address: 1800 Concord Pike, Wilmington, DE 19850.
Abstract
Although the principles of optimization of high-performance liquid chromatography (HPLC) have a long history starting with the work of Giddings in the 1960s and continuing with work by Knox and Guiochon extending into the 1990s we continue to see statements that flatly contradict theory. A prominent example is the notion that optimum “performance”, as measured by plate count, is always obtained by operating conventional length columns (e.g., 5−15 cm) at eluent velocities corresponding to the minimum plate height in the van Deemter curve. In the past decade the introduction of “Poppe plots” by Poppe and “kinetic plots” by Desmet and others has simplified the selection of “optimum” conditions, but it is evident that many workers are not entirely comfortable with this framework. Here we derive a set of simple, yet accurate, equations that allow rapid calculation of the column length and eluent velocity that will give either the maximum plate count in a given time or a given plate count in the shortest time. Equations are developed for the optimum column length, eluent velocity, and thus plate count for both the cases when particle size is preselected and when particle size is optimized along with eluent velocity and column length. Although both of these situations have been previously considered the implications of the resulting equations have not been previously made explicit. Lack of full understanding of the consequences of the differences between these two cases is very important and responsible for many erroneous conclusions. The simple closed-form equations that result from this work complement the graphical, iterative approaches of Poppe and Desmet; the resulting compact framework allows practitioners to rapidly and effectively find the operating parameters needed to achieve a specific separation goal in the shortest time and to compare emerging technologies (e.g., high pressure, high temperature, and different particle types) in terms of their impact on achievable plate counts and speeds in HPLC. A Web-based calculator based on the equations presented here is now available (http://homepages.gac.edu/
dstoll/calculators/optimize.html).
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 3 ACS Journal articles (3 most recent appear below).

Perspectives on Recent Advances in the Speed of High-Performance Liquid Chromatography
Peter W. Carr, Dwight R. Stoll, and Xiaoli WangAnalytical Chemistry2011 83 (6), 1890-1900Perspectives on Recent Advances in the Speed of High-Performance Liquid Chromatography
Peter W. Carr, Dwight R. Stoll, and Xiaoli WangAnalytical Chemistry2011 83 (6), 1890-1900Perhaps the most consistent trend in the development of high-performance liquid chromatography (HPLC) since its inception in the 1960s has been the continuing reach for ever faster analyses. The pioneering work of Knox, Horvath, Halasz, and Guiochon set ...

Plate Heights below 50 nm for Protein Electrochromatography Using Silica Colloidal Crystals
Bingchuan Wei, Douglas S. Malkin, and Mary J. WirthAnalytical Chemistry2010 82 (24), 10216-10221Plate Heights below 50 nm for Protein Electrochromatography Using Silica Colloidal Crystals
Bingchuan Wei, Douglas S. Malkin, and Mary J. WirthAnalytical Chemistry2010 82 (24), 10216-10221Silica colloidal crystals formed from 330 nm nonporous silica spheres inside of 75 μm i.d. fused silica capillaries were evaluated for the efficiency of capillary electrochromatography of proteins. Three proteins, ribonuclease A, cytochrome C, and ...

Capillary Ultrahigh Performance Liquid Chromatography with Elevated Temperature for Sub-One Minute Separations of Basal Serotonin in Submicroliter Brain Microdialysate Samples
Yansheng Liu, Jing Zhang, Xiaomi Xu, Moe K. Zhao, Anne M. Andrews, and Stephen G. WeberAnalytical Chemistry2010 82 (23), 9611-9616Capillary Ultrahigh Performance Liquid Chromatography with Elevated Temperature for Sub-One Minute Separations of Basal Serotonin in Submicroliter Brain Microdialysate Samples
Yansheng Liu, Jing Zhang, Xiaomi Xu, Moe K. Zhao, Anne M. Andrews, and Stephen G. WeberAnalytical Chemistry2010 82 (23), 9611-9616Improving the time resolution in microdialysis coupled to high performance liquid chromatography (HPLC) requires that the volume of the separation system be decreased. A low-volume separation permits smaller microdialysate volumes to be injected without ...
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Published In Issue July 01, 2009
- Article ASAPJune 08, 2009
- Received: January 19, 2009
Accepted: March 24, 2009
Cart


ACS
Network






