Article
Rapid, Direct Analysis of Cholesterol by Charge Labeling in Reactive Desorption Electrospray Ionization
Purchase the full-text
- PDF/HTML,
figures/images,
references and tables,
(where available)
Abstract
Direct and rapid analysis of cholesterol was accomplished in the ambient environment using reactive desorption electrospray ionization (DESI) mass spectrometry. This was achieved by electrospraying reagent solutions in the form of high velocity charged droplets at surfaces such as dried serum samples and animal tissue sections. Betaine aldehyde, incorporated into the spray solvent, reacts selectively and rapidly with the alcohol group of cholesterol by nucleophilic addition, forming a hemiacetal salt. Limits of detection for pure cholesterol and related compounds were
1 ng when a solution of cholesterol of 1 μg/mL was spotted onto the surface. Quantitative analysis of free cholesterol in serum using reactive DESI was demonstrated using cholesterol-d7 as internal standard. High throughput analysis of small volumes of serum spotted onto a suitable substrate was achieved at an analysis rate of
14 s per sample, with a relative standard deviation (RSD) of ca. 6%. Use of reactive DESI in the imaging mode allowed 2D spatial distributions of phospholipids and cholesterol to be recorded simultaneously in rat brain tissues.
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 10 ACS Journal articles (5 most recent appear below).

Infrared Laser Ablation Atmospheric Pressure Photoionization Mass Spectrometry
Anu Vaikkinen, Bindesh Shrestha, Tiina J. Kauppila, Akos Vertes, and Risto KostiainenAnalytical Chemistry2012 84 (3), 1630-1636Infrared Laser Ablation Atmospheric Pressure Photoionization Mass Spectrometry
Anu Vaikkinen, Bindesh Shrestha, Tiina J. Kauppila, Akos Vertes, and Risto KostiainenAnalytical Chemistry2012 84 (3), 1630-1636In this paper we introduce laser ablation atmospheric pressure photoionization (LAAPPI), a novel atmospheric pressure ion source for mass spectrometry. In LAAPPI the analytes are ablated from water-rich solid samples or from aqueous solutions with an ...

Desorption Electrospray Ionization then MALDI Mass Spectrometry Imaging of Lipid and Protein Distributions in Single Tissue Sections
Livia S. Eberlin, Xiaohui Liu, Christina R. Ferreira, Sandro Santagata, Nathalie Y.R. Agar, and R. Graham CooksAnalytical Chemistry2011 83 (22), 8366-8371Desorption Electrospray Ionization then MALDI Mass Spectrometry Imaging of Lipid and Protein Distributions in Single Tissue Sections
Livia S. Eberlin, Xiaohui Liu, Christina R. Ferreira, Sandro Santagata, Nathalie Y.R. Agar, and R. Graham CooksAnalytical Chemistry2011 83 (22), 8366-8371Imaging mass spectrometry (MS) is a powerful technique for mapping the spatial distributions of a wide range of chemical compounds simultaneously from a tissue section. Co-localization of the distribution of individual molecular species, including ...

Direct Plant Tissue Analysis and Imprint Imaging by Desorption Electrospray Ionization Mass Spectrometry
Thomas Müller, Sheran Oradu, Demian R. Ifa, R. Graham Cooks, and Bernhard KräutlerAnalytical Chemistry2011 Article ASAPDirect Plant Tissue Analysis and Imprint Imaging by Desorption Electrospray Ionization Mass Spectrometry
Thomas Müller, Sheran Oradu, Demian R. Ifa, R. Graham Cooks, and Bernhard KräutlerAnalytical Chemistry2011 Article ASAPThe ambient mass spectrometry technique, desorption electrospray ionization mass spectrometry (DESI-MS), is applied for the rapid identification and spatially resolved relative quantification of chlorophyll degradation products in complex senescent plant ...

Mapping Lipid Alterations in Traumatically Injured Rat Spinal Cord by Desorption Electrospray Ionization Imaging Mass Spectrometry
Marion Girod, Yunzhou Shi, Ji-Xin Cheng, and R. Graham CooksAnalytical Chemistry2011 83 (1), 207-215Mapping Lipid Alterations in Traumatically Injured Rat Spinal Cord by Desorption Electrospray Ionization Imaging Mass Spectrometry
Marion Girod, Yunzhou Shi, Ji-Xin Cheng, and R. Graham CooksAnalytical Chemistry2011 83 (1), 207-215Desorption electrospray ionization (DESI) mass spectrometry (MS) is used in an imaging mode to interrogate the lipid profiles of 15 μm thin tissue cross sections of injured rat spinal cord and normal healthy tissue. Increased relative intensities of fatty ...

Rapid and Selective Screening for Sulfhydryl Analytes in Plasma and Urine Using Surface-Enhanced Transmission Mode Desorption Electrospray Ionization Mass Spectrometry
Joseph E. Chipuk, Michael H. Gelb and Jennifer S. BrodbeltAnalytical Chemistry2010 82 (10), 4130-4139Rapid and Selective Screening for Sulfhydryl Analytes in Plasma and Urine Using Surface-Enhanced Transmission Mode Desorption Electrospray Ionization Mass Spectrometry
Joseph E. Chipuk, Michael H. Gelb and Jennifer S. BrodbeltAnalytical Chemistry2010 82 (10), 4130-4139Nylon mesh substrates were derivatized to include VICATSH, a biotinylated reagent that contains both a photolabile linking group and a thiol specific capture agent. The enhanced mesh substrates were then used to capture sulfhydryl analytes directly from ...
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Published In Issue September 15, 2009
- Article ASAPAugust 19, 2009
- Received: May 8, 2009
Accepted: July 31, 2009
Cart


ACS
Network






