Article
Online Fluorescence Suppression in Modulated Raman Spectroscopy
Purchase the full-text
- PDF/HTML,
figures/images,
references and tables,
(where available)
SUPA, School of Physics and Astronomy.
, ‡Bute Medical School.
Abstract
Label-free chemical characterization of single cells is an important aim for biomedical research. Standard Raman spectroscopy provides intrinsic biochemical markers for noninvasive analysis of biological samples but is often hindered by the presence of fluorescence background. In this paper, we present an innovative modulated Raman spectroscopy technique to filter out the Raman spectra from the fluorescence background. The method is based on the principle that the fluorescence background does not change whereas the Raman scattering is shifted by the periodical modulation of the laser wavelength. Exploiting this physical property and importantly the multichannel lock-in detection of the Raman signal, the modulation technique fulfills the requirements of an effective fluorescence subtraction method. Indeed, once the synchronization and calibration procedure is performed, minimal user intervention is required, making the method online and less time-consuming than the other fluorescent suppression methods. We analyze the modulated Raman signal and shifted excitation Raman difference spectroscopy (SERDS) signal of 2 μm-sized polystyrene beads suspended in a solution of fluorescent dye as a function of modulation rate. We show that the signal-to-noise ratio of the modulated Raman spectra at the highest modulation rate is 3 times higher than the SERDS one. To finally evaluate the real benefits of the modulated Raman spectroscopy, we apply our technique to Chinese hamster ovary cells (CHO). Specifically, by analyzing separate spectra from the membrane, cytoplasm, and nucleus of CHO cells, we demonstrate the ability of this method to obtain localized sensitive chemical information from cells, away from the interfering fluorescence background. In particular, statistical analysis of the Raman data and classification using PCA (principal component analysis) indicate that our method allows us to distinguish between different cell locations with higher sensitivity and specificity, avoiding potential misinterpretation of the data obtained using standard background procedures.
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 1 ACS Journal articles (1 most recent appear below).

Process Analytical Chemistry
Jerome Workman, Jr., Barry Lavine, Ray Chrisman, and Mel KochAnalytical Chemistry2011 83 (12), 4557-4578Process Analytical Chemistry
Jerome Workman, Jr., Barry Lavine, Ray Chrisman, and Mel KochAnalytical Chemistry2011 83 (12), 4557-4578
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Published In Issue January 15, 2010
- Article ASAPDecember 17, 2009
- Received: November 23, 2009
Accepted: November 23, 2009
Cart


ACS
Network






