Release of Low Molecular Weight Silicones and Platinum from Silicone Breast Implants

Ernest D. Lykissa, Subbarao V. Kala, Jennifer B. Hurley, and Russell M. Lebovitz*
Department of Pathology, Baylor College of Medicine, Houston, Texas 77030
Anal. Chem., 1997, 69 (23), pp 4912–4916
DOI: 10.1021/ac970710w
Publication Date (Web): December 1, 1997
Copyright © 1997 American Chemical Society
*

 Corresponding author:  (713)798-8161 (phone); (713)798-5838 (fax); lebovitz@pdq.net (e-mail).

Abstract

We have conducted a series of studies addressing the chemical composition of silicone gels from breast implants as well as the diffusion of low molecular weight silicones (LM-silicones) and heavy metals from intact implants into various surrounding media, namely, lipid-rich medium (soy oil), aqueous tissue culture medium (modified Dulbecco's medium, DMEM), or an emulsion consisting of DMEM plus 10% soy oil. LM-silicones in both implants and surrounding media were detected and quantitated using gas chromatography (GC) coupled with atomic emission (GC-AED) as well as mass spectrometric (GC/MS) detectors, which can detect silicones in the nanogram range. Platinum, a catalyst used in the preparation of silicone gels, was detected and quantitated using inductive argon-coupled plasma/mass spectrometry (ICP-MS), which can detect platinum in the parts per trillion range. Our results indicate that GC-detectable low molecular weight silicones contribute approximately 1−2% to the total gel mass and consist predominantly of cyclic and linear poly(dimethylsiloxanes) ranging from 3 to 20 siloxane [(CH3)2−Si−O] units (molecular weight 200−1500). Platinum can be detected in implant gels at levels of 700 μg/kg by ICP-MS. The major component of implant gels appears to be high molecular weight silicone polymers (HM-silicones) too large to be detected by GC. However, these HM-silicones can be converted almost quantitatively (80% by mass) to LM-silicones by heating implant gels at 150−180 °C for several hours. We also studied the rates at which LM-silicones and platinum leak through the intact implant outer shell into the surrounding media under a variety of conditions. Leakage of silicones was greatest when the surrounding medium was lipid-rich, and up to 10 mg/day LM-silicones was observed to diffuse into a lipid-rich medium per 250 g of implant at 37 °C. This rate of leakage was maintained over a 7-day experimental period. Similarly, platinum was also observed to leak through intact implants into lipid-containing media at rates of approximately 20−25 μg/day/250 g of implant at 37 °C. The rates at which both LM-silicones and platinum have been observed to leak from intact implants could lead to significant accumulation within lipid-rich tissues and should be investigated more fully in vivo.

Tools

History

  • Published In Issue December 01, 1997
  • Received for review July 7, 1997. Accepted September 30, 1997.

Recommend & Share

Related Content

Other ACS content by these authors: