A Practical Application of the Pb/PbO2 Cell: The Determination of the State of Charge of Lead-Acid Batteries

Milton D. Capelato , Neila M. Cassiano and Luis A. Ramos
Laboratorio de Eletroanalitica, Departmento de Quimica-Universidade Federal de Sao Carlos, Caixa Postal 676-CEP 13560-970 Sao Carlos, Sao Paulo, Brazil
J. Chem. Educ., 1995, 72 (9), p 845
DOI: 10.1021/ed072p845
Publication Date: September 1995

Abstract

A laboratory-made device to estimate the available charge of lead-acid batteries is proposed. It is based on a Pb/PbO2 potentiometric cell which potential is directly proportional to the electrolyte density which in turn, is related to the available capacity of the battery. Standard deviations less than 0.5% were obtained in relation to the traditional density measurements.