From Polarimeter to Contact Angle Goniometer - Inexpensive Conversion of Laboratory Equipment

Konrad G. Kabza and Kevin Cochran
Deparment of Chemistry, SUNY at Fredonia, Fredonia, NY 14063
J. Chem. Educ., 1997, 74 (3), p 322
DOI: 10.1021/ed074p322
Publication Date (Web): March 1, 1997

Abstract

Recent decades have brought about dramatic changes in the interests of chemical researchers. Interdisciplinary areas of chemistry such as environmental chemistry, polymer science, and material science have become important parts of the undergraduate curriculum. However, introduction of these multidisciplinary areas into classical chemistry curricula often requires acquisition of specialized analytical equipment. At the same time, more traditional characterization techniques such as polarimetry have been replaced by the routine use of FT-IR and GC-MS techniques in undergraduate organic chemistry laboratories. While such classical instruments remain serviceable, they have in many cases fallen into disuse. Here we describe a simple method whereby a polarimeter is converted into a contact angle goniometer.

Contact angle goniometry is an example of a traditional analytical tool that would be an asset to any physical chemistry training and that would still be of relevance to many interdisciplinary areas. Such instrumentation provides a simple and inexpensive way to introduce and measure fundamental properties such as the surface tension of a variety of materials including metals and polymers. Contact angle measurements are indispensable in the study of adhesion, wettability, and liquid thermodynamics (1 - 3). Many experiments using such measurements can be devised for traditional physical chemistry laboratory sequences. The concept of surface energy is important in materials science, chemistry, and physics. Thus it could not only enhance students' learning but also provide them with new perspective on the fascinating field of surface chemistry and physics.

Keywords (Audience):

Upper-Division Undergraduate

Keywords (Domain):

Physical Chemistry

Keywords (Subject):

Laboratory Equipment / Apparatus

Citing Articles

Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.

This article has been cited by 3 ACS Journal articles (3 most recent appear below).

  • Cover Image

    Axisymmetric Liquid Hanging Drops

    Tatiana Yu. Latychevskaia , Erich C. Meister
    Journal of Chemical Education2006 83 (1), 117
    • Axisymmetric Liquid Hanging Drops

      Tatiana Yu. Latychevskaia , Erich C. Meister
      Journal of Chemical Education2006 83 (1), 117

      The formation of liquid drops delivered from a circular capillary has found application in drop-volume tensiometers ranging from the early stalagmometer to more recent computer-controlled instruments. Although the phenomenon of drop formation can be ...

  • Cover Image

    Contact Angle Goniometry as a Tool for Surface Tension Measurements of Solids, Using Zisman Plot Method. A Physical Chemistry Experiment

    Konrad G. Kabza , Jason E. Gestwicki and Jessica L. McGrath
    Journal of Chemical Education2000 77 (1), 63
    • Contact Angle Goniometry as a Tool for Surface Tension Measurements of Solids, Using Zisman Plot Method. A Physical Chemistry Experiment

      Konrad G. Kabza , Jason E. Gestwicki and Jessica L. McGrath
      Journal of Chemical Education2000 77 (1), 63

      The paper describes a physical chemistry experiment for measurement of surface tension of solids. It includes description of the Zisman-plot method for obtaining the surface tensions of solids as well as a detailed experimental procedure for surface ...

  • Cover Image

    A Surface Chemistry Experiment Using an Inexpensive Contact Angle Goniometer

    Madalena Dionísio and João Sotomayor
    Journal of Chemical Education2000 77 (1), 59
    • A Surface Chemistry Experiment Using an Inexpensive Contact Angle Goniometer

      Madalena Dionísio and João Sotomayor
      Journal of Chemical Education2000 77 (1), 59

      The first part of this work presents the construction of an inexpensive and easy to handle contact angle goniometer. The instrument provides contact angles that are within ±2° of the values obtained by a commercial apparatus and are in good agreement ...

Tools

SciFinder Links

SciFinder subscribers:  Click to sign in | Not a SciFinder subscriber? Learn more at www.cas.org

Explore by:


History

  • Received: August 03, 2009

Recommend & Share

  • Share on ACS NetworkACS Network
  • Add to FacebookFacebook
  • Tweet ThisTweet This
  • Add to CiteULikeCiteULike
  • Add to NewsvineNewsvine
  • Digg ThisDigg This
  • Add to DeliciousDelicious

Related Content