Article
The Flawed Nature of the Calibration Factor in Breath-Alcohol Analysis
Purchase the full-text
- PDF/HTML,
figures/images,
references and tables,
(where available)
Abstract
Breath-alcohol analyzers used by law enforcement agencies to evaluate suspected driving-while-intoxicated (DWI) drivers are routinely calibrated with standard, dilute aqueous solutions of ethanol known as simulator solutions. The analyzers are deemed accurate if they generate results within an established margin of error consistent with ethanol concentrations equivalent to the actual concentrations of the simulator solutions. The fundamental flaw of this protocol is that it ignores the fact that a simulator solution is an ideal Henry’s law system, whereas a human test subject is not. Since breath-alcohol analysis is an application of Henry’s law, the level of accuracy ascribed to simulator-based calibrations cannot be applied to analyses involving humans because they are affected by physiological variables that can significantly impact the results of such analyses. This article addresses the importance of these variables, including blood:breath ratio variability, body temperature, and breathing pattern. Moreover, the article notes that, when standard ethanol-in-nitrogen compressed gas mixtures are used instead of aqueous simulator solutions to calibrate breath-alcohol analyzers, the same limitations of accuracy apply. Finally, emphasis is placed on the nature of the ideal calibration standard, namely that it should mimic the system to be analyzed, which is clearly not the case with the calibration protocol employed in breath-alcohol analysis.
Keywords (Audience):
Second-Year UndergraduateKeywords (Domain):
Analytical ChemistryKeywords (Subject):
Drugs / PharmaceuticalsCiting Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 1 ACS Journal articles (1 most recent appear below).

Variables That Impact on the Results of Breath-Alcohol Tests
Dominick A. LabiancaJournal of Chemical Education2004 81 (10), 1420Variables That Impact on the Results of Breath-Alcohol Tests
Dominick A. LabiancaJournal of Chemical Education2004 81 (10), 1420Clarifies information presented in a recent articles describing an experiment involving breath–alcohol analysis using an FTIR spectrometer.
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Received: August 03, 2009
Cart

ACS
Network