A senior-level undergraduate laboratory experiment that demonstrates the use of solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS) was developed for the quantitative determination of bromoform in swimming pool water. Bromoform was extracted by SPME from the headspace of vials containing sodium chloride-saturated swimming pool water. Bromoform concentrations were determined from comparisons of peak areas on a student-generated calibration curve. Students compared results to OSHA water and air exposure limits for bromoform.
Citing Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 7 ACS Journal articles (5 most recent appear below).

An Advanced Analytical Chemistry Experiment Using Gas Chromatography−Mass Spectrometry, MATLAB, and Chemometrics To Predict Biodiesel Blend Percent Composition
Karisa M. Pierce, Stephen P. Schale, Trang M. Le, and Joel C. LarsonJournal of Chemical Education2011 88 (6), 806-810An Advanced Analytical Chemistry Experiment Using Gas Chromatography−Mass Spectrometry, MATLAB, and Chemometrics To Predict Biodiesel Blend Percent Composition
Karisa M. Pierce, Stephen P. Schale, Trang M. Le, and Joel C. LarsonJournal of Chemical Education2011 88 (6), 806-810We present a laboratory experiment for an advanced analytical chemistry course where we first focus on the chemometric technique partial least-squares (PLS) analysis applied to one-dimensional (1D) total-ion-current gas chromatography−mass spectrometry (...

The Garden of Green Organic Chemistry at Hendrix College
Thomas E. Goodwin2009 1011 (), 37-53The Garden of Green Organic Chemistry at Hendrix College
Thomas E. Goodwin2009 1011 (), 37-53The Hendrix College organic chemistry laboratories were converted to microscale experiments in 1988 to minimize possible adverse environmental impact, increase lab safety, and decrease generation of waste and costs of waste disposal. As we became aware of ...

Emerging Technologies for Identification of Disinfection Byproducts: GC/FT−ICR MS Characterization of Solvent Artifacts
Caleb Heffner, Indira Silwal, John M. Peckenham, and Touradj SoloukiEnvironmental Science & Technology2007 41 (15), 5419-5425Emerging Technologies for Identification of Disinfection Byproducts: GC/FT−ICR MS Characterization of Solvent Artifacts
Caleb Heffner, Indira Silwal, John M. Peckenham, and Touradj SoloukiEnvironmental Science & Technology2007 41 (15), 5419-5425Water samples from a local water treatment plant were analyzed, using gas chromatography Fourier transform ion cyclotron resonance mass spectrometry (GC/FT−ICR MS), to identify potential disinfection byproducts (DBPs). Both liquid−liquid extraction (LLE) ...

The Chemistry of Swimming Pool Maintenance
Carl Salter and David L. LanghusJournal of Chemical Education2007 84 (7), 1124The Chemistry of Swimming Pool Maintenance
Carl Salter and David L. LanghusJournal of Chemical Education2007 84 (7), 1124Swimming pool maintenance is an interesting chemical application that is appropriate for discussion in general chemistry courses. This paper examines the key ideas behind swimming pool chemistry—the central importance of pH and its effect on chlorine ...

Identification of Glue Vapors Using Electron Impact and Chemical Ionization Modes in GC–MS
Jeremy Richer , John Spencer and Michael BairdJournal of Chemical Education2006 83 (8), 1196Identification of Glue Vapors Using Electron Impact and Chemical Ionization Modes in GC–MS
Jeremy Richer , John Spencer and Michael BairdJournal of Chemical Education2006 83 (8), 1196The analysis of the vapors from six commercial glues provided an interesting and challenging lab assignment for students in an instrumental analysis laboratory course. Students used both electron impact (EI) and chemical ionization (CI) modes of operation ...
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Received: August 03, 2009
Cart

ACS
Network