Article
A Simplified Calculation of the Real Confidence Interval in Analytical Methods
Purchase the full-text
- PDF/HTML,
figures/images,
references and tables,
(where available)
Abstract
This paper describes a detailed study of the imprecision of an analytical method resulting from the quantification step. Students use a mathematical model we developed to discover the effect of the different parameters on this imprecision. After applying this method with students we reached three main conclusions. First, the imprecision does not depend on the slope of the calibration line. Second, the imprecision does depend on the number (n) and the concentration of the calibration standards used, the analyte concentration in the sample to be analyzed, and the correlation coefficient (r) of the calibration line. Third, when the concentration of the calibration standards are equally spaced and the analyte concentration in the sample is close to the centroid of the line, the imprecision depends only on the n and r values. This model allows students to calculate imprecision more easily so that they will be able to apply this mathematical model both in their studies and their future professional activities.
Keywords (Audience):
Second-Year UndergraduateKeywords (Domain):
Analytical ChemistryKeywords (Feature):
Chemical Education ResearchKeywords (Subject):
Quantitative AnalysisCiting Articles
Citation data is made available by participants in CrossRef's Cited-by Linking service. For a more comprehensive list of citations to this article, users are encouraged to perform a search in SciFinder.
This article has been cited by 2 ACS Journal articles (2 most recent appear below).

Sampling the Soils Around a Residence Containing Lead-Based Paints: An X-ray Fluorescence Experiment
Steven J. BachoferJournal of Chemical Education2008 85 (7), 980Sampling the Soils Around a Residence Containing Lead-Based Paints: An X-ray Fluorescence Experiment
Steven J. BachoferJournal of Chemical Education2008 85 (7), 980Sampling experiments utilizing field portable instruments are instructional since students collect data following regulatory protocols, evaluate it, and begin to recognize their civic responsibilities upon collecting useful data. A lead-in-soil experiment ...

Quantitative Comparison of Three Standardization Methods Using a One-Way ANOVA for Multiple Mean Comparisons
Russell D. BarrowsJournal of Chemical Education2007 84 (5), 839Quantitative Comparison of Three Standardization Methods Using a One-Way ANOVA for Multiple Mean Comparisons
Russell D. BarrowsJournal of Chemical Education2007 84 (5), 839The use of an external standard calibration curve, standard addition, and internal standard methods for quantitatively determining the concentration of analytes is important to the study of analytical chemistry, especially in the area of instrumental ...
Tools
-
Add to Favorites
-
Download Citation
-
Email a Colleague -
Permalink
Order Reprints
Rights & Permissions
Citation Alerts
History
- Received: August 03, 2009
Cart

ACS
Network






