Application of Isotope Dilution Gas Chromatography−Mass Spectrometry in Analysis of Organochlorine Pesticide Residues in Ginseng Root

Serena Chan, Mei-Fong Kong, Yiu-Chung Wong, Siu-Kay Wong, and Della W. M. Sin*
Analytical and Advisory Services Division, Government Laboratory of the Hong Kong Special Administrative Region (HKSAR), Homantin Government Offices, 88 Chung Hau Street, Homantin, Hong Kong
J. Agric. Food Chem., 2007, 55 (9), pp 3339–3345
DOI: 10.1021/jf0637168
Publication Date (Web): April 4, 2007
Copyright © 2007 American Chemical Society
*

 To whom correspondence should be addressed. E-mail: wmsin@govtlab.gov.hk.

Abstract

A highly accurate and precise method based on isotope dilution gas chromatography−mass spectrometry was developed for the determination of five matrix-bound organochlorine pesticides, namely, hexachlorobenzene and hexachlorocyclohexanes (α-, β-, δ-, and γ- isomers), in a reference sample of Panax gingseng. Identification of the analytes was confirmed under selective ion monitoring mode by the presence of two dominant ion fragments within the specific time windows (±1% of the relative retention time with respect to the calibration standards) and matching of relative ion intensities of the concerned ions in samples and calibration standards (within ±5%). Quantification was based on the measurement of concentration ratios of the natural and isotopic analogues in the sample and calibration blends. To circumvent the tedious iterative process of exact isotope matching that is often used in isotope dilution mass spectrometry analysis, a single-point calibration procedure was adopted with the isotopic amount ratios in the sample and calibration blends close to unity (0.9−1.1). Under the described approach, intraday and interday repeatability of replicate analyses of organochlorine pesticides in the ginseng root sample were below 1.4%. The expanded relative uncertainty ranging from 4.0 to 6.5% at a coverage factor of 2 was significantly lower than those of conventional gas chromatographic methods using other calibration techniques (internal or external standards). A deviation of less than 2.0% from the certified values was achieved when applying the developed method to determine hexachlorobenzene, α-, and β-hexachlorocyclohexane in a certified reference material (CRM), BCR-CRM 115. Because of the unavailability of relevant CRMs of herbal origins, the concerned ginseng root sample, after verification of the “true values” of the concerned organochlorine pesticides by the valid primary method, is suitable for serving as an in-house reference material for quality assurance and method validation purposes.

Keywords: Organochlorine pesticides; hexachlorobenzene; hexachlorocyclohexanes; isotope dilution; ginseng root; IDMS

Tools

History

  • Published In Issue May 02, 2007
  • Received for review December 21, 2006. Revised manuscript received February 28, 2007. Accepted March 06, 2007. The contents of this paper do not necessarily reflect the views of the Government of the HKSAR nor does mention of trade names or commercial products constitute endorsement or recommendations of use.

Recommend & Share

Related Content

Other ACS content by these authors: