Multiplexed Two-Dimensional Liquid Chromatography for MALDI and Nanoelectrospray Ionization Mass Spectrometry in Proteomics

Haruna Saito, Yoshiya Oda, Toshitaka Sato, Junro Kuromitsu, and Yasushi Ishihama*
Laboratory of Seeds Finding Technology, Eisai Co., Ltd., 5-1-3 Tokodai, Tsukuba, Ibaraki 300-2635, Japan
J. Proteome Res., 2006, 5 (7), pp 1803–1807
DOI: 10.1021/pr0601178
Publication Date (Web): June 20, 2006
Copyright © 2006 American Chemical Society
*

 To whom correspondence should be addressed. Tel:  +81 235 29 0534. Fax:  +81 235 29 0536. E-mail:  y-ishi@ttck.keio.ac.jp.

,

 Current address:  Institute for Advanced Biosciences, Keio University, 403-1 Nipponkoku, Daihouji, Tsuruoka 997-0017, Japan.

Abstract

Abstract Image

We developed a multiplexed two-dimensional separation system based on reversed phase (RP) − strong cation exchange (SCX) chromatography as a front-end device for matrix-assisted laser desorption ionization (MALDI) or nanoelectrospray ionization (nanoESI) mass spectrometry. Tryptic peptide mixtures were fractionated on a reversed-phase HPLC column, and each fraction was loaded onto multiplexed SCX microcolumns. Because this second chromatography was carried out in parallel, the analysis time is independent of the fraction number in the first RP−HPLC separation. The resultant samples were desalted/concentrated and eluted onto a MALDI plate with matrix-containing elution solutions in parallel, or eluted with optimized solutions for nanoESI and loaded onto nanoESI sprayers by an automated instrument. The soluble portion of HCT116 lysate was digested and fractionated using a 48-plexed chromatography system. Approximately 1000 unique peaks were detected in MALDI−MS with 3000 MS/MS spectra, while 724 peptides with ultrahigh peptide mass accuracy (sub-ppm error) were identified in nanoESI−FTICR mass spectrometry with five integrated selected ion monitoring scans. Since MS measurement with this off-line LC−LC approach is not restricted by continuous LC elution, it is expected to be useful especially in cases where repeated analysis with different scan modes or long-term data acquisition is required.

Keywords: multiplexed chromatography • two-dimensional chromatography • StageTip • C18−SCX fractionation • proteomics • MALDI−MS • nanoelectrospray−MS • HCT116

Tools

SciFinder Links

SciFinder subscribers:  Click to sign in | Not a SciFinder subscriber? Learn more at www.cas.org

History

  • Published In Issue July 07, 2006
  • Received March 27, 2006

Recommend & Share

Related Content

Other ACS content by these authors: