Rotating Disk Potentiometry for Inner Solution Optimization of Low-Detection-Limit Ion-Selective Electrodes

View Author Information
Department of Chemistry, Auburn University, Auburn, Alabama 36849
Cite this: Anal. Chem. 2003, 75, 24, 6922–6931
Publication Date (Web):October 31, 2003
https://doi.org/10.1021/ac0346961
Copyright © 2003 American Chemical Society

    Article Views

    435

    Altmetric

    -

    Citations

    LEARN ABOUT THESE METRICS
    Other access options

    Abstract

    The extent of optimization of the lower detection limit of ion-selective electrodes (ISEs) can be assessed with an elegant new method. At the detection limit (i.e., in the absence of primary ions in the sample), one can observe a reproducible change in the membrane potential upon alteration of the aqueous diffusion layer thickness. This stir effect is predicted to depend on the composition of the inner solution, which is known to influence the lower detection limit of the potentiometric sensor dramatically. For an optimized electrode, the stir effect is calculated to be exactly one-half the value of the case when substantial coextraction occurs at the inner membrane side. In contrast, there is no stir effect when substantial ion exchange occurs at the inner membrane side. Consequently, this experimental method can be used to determine how well the inner filling solution has been optimized. A rotating disk electrode was used in this study because it provides adequate control of the aqueous diffusion layer thickness. Various ion-selective membranes with a variety of inner solutions that gave different calculated concentrations of the complex at the inner membrane side were studied to evaluate this principle. They contained the well-examined silver ionophore O,O‘ ‘-bis[2-(methylthio)ethyl]-tert-butylcalix[4]arene, the potassium ionophore valinomycin, or the iodide carrier [9]mercuracarborand-3. Stir effects were determined in different background solutions and compared to theoretical expectations. Correlations were good, and the results encourage the use of such stir-effect measurements to optimize ISE compositions for real-world applications. The technique was also found to be useful in estimating the level of primary ion impurities in the sample. For an iodide-selective electrode measured in phosphoric acid, for example, apparent iodide impurity levels were calculated as 5 × 10-10 M.

    Read this article

    To access this article, please review the available access options below.

    Get instant access

    Purchase Access

    Read this article for 48 hours. Check out below using your ACS ID or as a guest.

    Recommended

    Access through Your Institution

    You may have access to this article through your institution.

    Your institution does not have access to this content. You can change your affiliated institution below.

     Present address:  Department of Chemistry, Brooklyn CollegeCUNY, Brooklyn, NY 11210.

    *

    In papers with more than one author, the asterisk indicates the name of the author to whom inquiries about the paper should be addressed.

    Cited By

    This article is cited by 28 publications.

    1. Lajos Höfler, Iwona Bedlechowicz, Tamás Vigassy, Róbert E. Gyurcsányi, Eric Bakker, and Ernö Pretsch . Limitations of Current Polarization for Lowering the Detection Limit of Potentiometric Polymeric Membrane Sensors. Analytical Chemistry 2009, 81 (9) , 3592-3599. https://doi.org/10.1021/ac802588j
    2. Maria A. Peshkova, Tomasz Sokalski, Konstantin N. Mikhelson and Andrzej Lewenstam . Obtaining Nernstian Response of a Ca2+-Selective Electrode in a Broad Concentration Range by Tuned Galvanostatic Polarization. Analytical Chemistry 2008, 80 (23) , 9181-9187. https://doi.org/10.1021/ac8013143
    3. Johan Bobacka,, Ari Ivaska, and, Andrzej Lewenstam. Potentiometric Ion Sensors. Chemical Reviews 2008, 108 (2) , 329-351. https://doi.org/10.1021/cr068100w
    4. Wittaya Ngeontae,, Yida Xu,, Chao Xu,, Wanlapa Aeungmaitrepirom,, Thawatchai Tuntulani,, Ernö Pretsch, and, Eric Bakker. Sensitivity and Working Range of Backside Calibration Potentiometry. Analytical Chemistry 2007, 79 (22) , 8705-8711. https://doi.org/10.1021/ac071248a
    5. Karin Y. Chumbimuni-Torres,, Nastassia Rubinova,, Aleksandar Radu,, Lauro T. Kubota, and, Eric Bakker. Solid Contact Potentiometric Sensors for Trace Level Measurements. Analytical Chemistry 2006, 78 (4) , 1318-1322. https://doi.org/10.1021/ac050749y
    6. Katarzyna Wygladacz,, Aleksandar Radu,, Chao Xu,, Yu Qin, and, Eric Bakker. Fiber-Optic Microsensor Array Based on Fluorescent Bulk Optode Microspheres for the Trace Analysis of Silver Ions. Analytical Chemistry 2005, 77 (15) , 4706-4712. https://doi.org/10.1021/ac050856s
    7. Tamás Vigassy,, Christian G. Huber,, Reiner Wintringer, and, Ernö Pretsch. Monolithic Capillary-Based Ion-Selective Electrodes. Analytical Chemistry 2005, 77 (13) , 3966-3970. https://doi.org/10.1021/ac050424h
    8. Aleksandar Radu,, Amnon J. Meir, and, Eric Bakker. Dynamic Diffusion Model for Tracing the Real-Time Potential Response of Polymeric Membrane Ion-Selective Electrodes. Analytical Chemistry 2004, 76 (21) , 6402-6409. https://doi.org/10.1021/ac049348t
    9. Eric Bakker. Electrochemical Sensors. Analytical Chemistry 2004, 76 (12) , 3285-3298. https://doi.org/10.1021/ac049580z
    10. Koji TOHDA, Naoki HOSOKAWA, Thi Hong Nhung DAO, Akira KANNO. Development a Flow Rinsing System for Improving the Detection Limit of Solvent Polymeric Membrane Ion-selective Electrodes. BUNSEKI KAGAKU 2018, 67 (5) , 239-247. https://doi.org/10.2116/bunsekikagaku.67.239
    11. Russell N. Grimes. Carboranes in Other Applications. 2016, 985-1019. https://doi.org/10.1016/B978-0-12-801894-1.00017-2
    12. Tomasz Sokalski. Transmembrane Ion Fluxes for Lowering Detection Limit of Ion‐Selective Electrodes. 2015, 23-59. https://doi.org/10.1002/9781118899076.ch2
    13. Piotr Gryczan, Agata Michalska, Krzysztof Maksymiuk. A simple currentless method of determination of ion fluxes to and within electroactive ion-exchange membranes. Journal of Solid State Electrochemistry 2014, 18 (8) , 2131-2138. https://doi.org/10.1007/s10008-014-2464-5
    14. Konstantin N. Mikhelson. Modern Trends in the ISEs Theory and Applications. 2013, 125-134. https://doi.org/10.1007/978-3-642-36886-8_7
    15. Russell N. Grimes. Carboranes in other applications. 2011, 1083-1105. https://doi.org/10.1016/B978-0-12-374170-7.00001-X
    16. K. N. Mikhelson. Ion-selective electrodes with sensitivity in strongly diluted solutions. Journal of Analytical Chemistry 2010, 65 (2) , 112-116. https://doi.org/10.1134/S1061934810020024
    17. En-Ping Luo, Ya-Qing Chai, Ruo Yuan, Jian-Yuan Dai, Lan Xu. Highly salicylate-selective membrane electrode based on a new thiomacrocyclic Schiff base complex of binuclear copper(II) as neutral carrier. Desalination 2009, 249 (2) , 615-620. https://doi.org/10.1016/j.desal.2008.12.054
    18. K. N. Mikhel’son. Electrochemical sensors based on ionophores: Current state, trends, and prospects. Russian Journal of General Chemistry 2008, 78 (12) , 2445-2454. https://doi.org/10.1134/S1070363208120268
    19. Katarzyna Wygladacz, Yu Qin, Wojciech Wroblewski, Eric Bakker. Phosphate-selective fluorescent sensing microspheres based on uranyl salophene ionophores. Analytica Chimica Acta 2008, 614 (1) , 77-84. https://doi.org/10.1016/j.aca.2008.02.069
    20. W.E. Morf, E. Pretsch, N.F. De Rooij. Computer simulation of ion-selective membrane electrodes and related systems by finite-difference procedures. Journal of Electroanalytical Chemistry 2007, 602 (1) , 43-54. https://doi.org/10.1016/j.jelechem.2006.11.025
    21. Aleksandar Radu, Shane Peper, Eric Bakker, Dermot Diamond. Guidelines for Improving the Lower Detection Limit of Ion‐Selective Electrodes: A Systematic Approach. Electroanalysis 2007, 19 (2-3) , 144-154. https://doi.org/10.1002/elan.200603741
    22. Aleksandar Radu, Dermot Diamond. Chapter 2 Ion-selective electrodes in trace level analysis of heavy metals: Potentiometry for the XXI century. 2007, 25-52. https://doi.org/10.1016/S0166-526X(06)49002-4
    23. Katarzyna Wygladacz, Eric Bakker. Fluorescent microsphere fiber optic microsensor array for direct iodide detection at low picomolar concentrations. The Analyst 2007, 132 (3) , 268. https://doi.org/10.1039/b614562k
    24. E.-P. Luo, Y.-Q. Chai, R. Yuan. Unsymmetrical Tetradentate Schiff Bases Copper (II) Complex as Neutral Carrier for Thiocyanate‐Selective Electrode. Analytical Letters 2007, 40 (2) , 369-386. https://doi.org/10.1080/00032710600964742
    25. Zsófia Szigeti, Tamás Vigassy, Eric Bakker, Ernö Pretsch. Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion‐Selective Electrodes. Electroanalysis 2006, 18 (13-14) , 1254-1265. https://doi.org/10.1002/elan.200603539
    26. Aleksandar Radu, Shane Peper, Chad Gonczy, Wolfgang Runde, Dermot Diamond. Trace‐Level Determination of Cs + Using Membrane‐Based Ion‐Selective Electrodes. Electroanalysis 2006, 18 (13-14) , 1379-1388. https://doi.org/10.1002/elan.200603542
    27. Matthew S. Messick, Sandeep K. Krishnan, Matthew K. Hulvey, Erich D. Steinle. Development of anion selective polymer membrane electrodes based on lutetium(III) porphyrins. Analytica Chimica Acta 2005, 539 (1-2) , 223-228. https://doi.org/10.1016/j.aca.2005.03.049
    28. Eric Bakker, Ernö Pretsch. Potentiometric sensors for trace-level analysis. TrAC Trends in Analytical Chemistry 2005, 24 (3) , 199-207. https://doi.org/10.1016/j.trac.2005.01.003

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    You’ve supercharged your research process with ACS and Mendeley!

    STEP 1:
    Click to create an ACS ID

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    MENDELEY PAIRING EXPIRED
    Your Mendeley pairing has expired. Please reconnect