ACS Publications. Most Trusted. Most Cited. Most Read
My Activity
CONTENT TYPES

Comprehensive Off-Line, Two-Dimensional Liquid Chromatography. Application to the Separation of Peptide Digests

View Author Information
Department of Chemistry, The University of Tennessee, Knoxville, Tennessee 37996-1600, and Division of Chemical Sciences, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
Cite this: Anal. Chem. 2008, 80, 8, 2756–2767
Publication Date (Web):March 21, 2008
https://doi.org/10.1021/ac7022662
Copyright © 2008 American Chemical Society

    Article Views

    676

    Altmetric

    -

    Citations

    LEARN ABOUT THESE METRICS
    Read OnlinePDF (346 KB)

    Abstract

    The separation of the peptide digests of myoglobin and bovine serum albumin was performed with an off-line combination of two commercial, conventional HPLC columns. The first column was packed with a strong ion exchanger and eluted with a KCl gradient. The second column was packed with particles of C18-bonded silica and eluted with an acetonitrile gradient. The conditional peak capacities of the 2D separations achieved exceed 7000 under the experimental conditions investigated. This performance is achieved at the cost of an analysis time of the order of 28 hours. Possible improvements to the separation method described here are discussed.

     Present address:  Department of Chemistry, University of Ferrara, via L. Borsari 46, 44100 Ferrara, Italy.

    *

     To whom correspondence should be addressed. Tel.:  +1-865-974-0733. Fax:, +1-865-974-2667. E-mail:  [email protected].

    Cited By

    This article is cited by 43 publications.

    1. Weili Miao, Lin Li, Yinsheng Wang. A Targeted Proteomic Approach for Heat Shock Proteins Reveals DNAJB4 as a Suppressor for Melanoma Metastasis. Analytical Chemistry 2018, 90 (11) , 6835-6842. https://doi.org/10.1021/acs.analchem.8b00986
    2. Simon S. Jakobsen, Jan H. Christensen, Sylvain Verdier, Claude R. Mallet, and Nikoline J. Nielsen . Increasing Flexibility in Two-Dimensional Liquid Chromatography by Pulsed Elution of the First Dimension: A Proof of Concept. Analytical Chemistry 2017, 89 (17) , 8723-8730. https://doi.org/10.1021/acs.analchem.7b00758
    3. Andrea F. G. Gargano, Mike Duffin, Pablo Navarro, and Peter J. Schoenmakers . Reducing Dilution and Analysis Time in Online Comprehensive Two-Dimensional Liquid Chromatography by Active Modulation. Analytical Chemistry 2016, 88 (3) , 1785-1793. https://doi.org/10.1021/acs.analchem.5b04051
    4. Zhong-Da Zeng, Helmut M. Hugel, and Philip J. Marriott . A Modeling Approach for Orthogonality of Comprehensive Two-Dimensional Separations. Analytical Chemistry 2013, 85 (13) , 6356-6363. https://doi.org/10.1021/ac400736v
    5. Marcelo R. Filgueira, Yuan Huang, Klaus Witt, Cecilia Castells, and Peter W. Carr . Improving Peak Capacity in Fast Online Comprehensive Two-Dimensional Liquid Chromatography with Post-First-Dimension Flow Splitting. Analytical Chemistry 2011, 83 (24) , 9531-9539. https://doi.org/10.1021/ac202317m
    6. Krisztián Horváth, Jacob N. Fairchild and Georges Guiochon . Generation and Limitations of Peak Capacity in Online Two-Dimensional Liquid Chromatography. Analytical Chemistry 2009, 81 (10) , 3879-3888. https://doi.org/10.1021/ac802694c
    7. P.N. Nesterenko. Ion chromatography. 2023, 465-507. https://doi.org/10.1016/B978-0-323-99968-7.00021-7
    8. Isabelle Kohler, Michel Verhoeven, Rob Haselberg, Andrea F.G. Gargano. Hydrophilic interaction chromatography – mass spectrometry for metabolomics and proteomics: state-of-the-art and current trends. Microchemical Journal 2022, 175 , 106986. https://doi.org/10.1016/j.microc.2021.106986
    9. Jelle De Vos, Dwight Stoll, Stephan Buckenmaier, Sebastiaan Eeltink, James P. Grinias. Advances in ultra‐high‐pressure and multi‐dimensional liquid chromatography instrumentation and workflows. Analytical Science Advances 2021, 2 (3-4) , 171-192. https://doi.org/10.1002/ansa.202100007
    10. Shuai Ji, Zhan-Zhong Liu, Jing Wu, Yan Du, Zhen-Yu Su, Tian-Yun Wang, Jie Han, Dong-Zhi Yang, Meng-Zhe Guo, Dao-Quan Tang. Chemical Profiling and Comparison of Sangju Ganmao Tablet and Its Component Herbs Using Two-Dimensional Liquid Chromatography to Explore Compatibility Mechanism of Herbs. Frontiers in Pharmacology 2018, 9 https://doi.org/10.3389/fphar.2018.01167
    11. Ahmed Ramzi, Hamid Ahmadi, Ioannis Sadiktsis, Ulrika Nilsson. A two-dimensional non-comprehensive reversed/normal phase high-performance liquid chromatography/tandem mass spectrometry system for determination of limonene and linalool hydroperoxides. Journal of Chromatography A 2018, 1566 , 102-110. https://doi.org/10.1016/j.chroma.2018.06.056
    12. Martina Catani, Simona Felletti, Omar H. Ismail, Francesco Gasparrini, Luisa Pasti, Nicola Marchetti, Chiara De Luca, Valentina Costa, Alberto Cavazzini. New frontiers and cutting edge applications in ultra high performance liquid chromatography through latest generation superficially porous particles with particular emphasis to the field of chiral separations. Analytical and Bioanalytical Chemistry 2018, 410 (10) , 2457-2465. https://doi.org/10.1007/s00216-017-0842-4
    13. Duxin Li, Cornelia Jakob, Oliver Schmitz. Practical considerations in comprehensive two-dimensional liquid chromatography systems (LCxLC) with reversed-phases in both dimensions. Analytical and Bioanalytical Chemistry 2015, 407 (1) , 153-167. https://doi.org/10.1007/s00216-014-8179-8
    14. Peter Kilz, Wolfgang Radke. Application of two-dimensional chromatography to the characterization of macromolecules and biomacromolecules. Analytical and Bioanalytical Chemistry 2015, 407 (1) , 193-215. https://doi.org/10.1007/s00216-014-8266-x
    15. C. J. Venkatramani, James Girotti, Larry Wigman, Nicholas Chetwyn. Assessing stability-indicating methods for coelution by two-dimensional liquid chromatography with mass spectrometric detection. Journal of Separation Science 2014, 37 (22) , 3214-3225. https://doi.org/10.1002/jssc.201400590
    16. Amélie D’Attoma, Sabine Heinisch. On-line comprehensive two dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part II: Application to the separation of peptides. Journal of Chromatography A 2013, 1306 , 27-36. https://doi.org/10.1016/j.chroma.2013.07.048
    17. Pyong-Gon Moon, Mi Hee Kwack, Jeong-Eun Lee, Young-Eun Cho, Ji-Hwan Park, Daehee Hwang, Moon Kyu Kim, Jung Chul Kim, Young Kwan Sung, Moon-Chang Baek. Proteomic analysis of balding and non-balding mesenchyme-derived dermal papilla cells from androgenetic alopecia patients using on-line two-dimensional reversed phase-reversed phase LC–MS/MS. Journal of Proteomics 2013, 85 , 174-191. https://doi.org/10.1016/j.jprot.2013.04.004
    18. Arianne Soliven, Imad A. Haidar Ahmad, Marcelo R. Filgueira, Peter W. Carr. Optimization of gradient reversed phase chromatographic peak capacity for low molecular weight solutes. Journal of Chromatography A 2013, 1273 , 57-65. https://doi.org/10.1016/j.chroma.2012.11.068
    19. Junyan Xu, Xiuli Zhang, Zhimou Guo, Jingyu Yan, Long Yu, Xiuling Li, Xingya Xue, Xinmiao Liang. Orthogonal separation and identification of long-chain peptides from scorpion Buthus martensi Karsch venom by using two-dimensional mixed-mode reversed phase-reversed phase chromatography coupled to tandem mass spectrometry. The Analyst 2013, 138 (6) , 1835. https://doi.org/10.1039/c2an36704a
    20. Pavel Jandera. Programmed elution in comprehensive two-dimensional liquid chromatography. Journal of Chromatography A 2012, 1255 , 112-129. https://doi.org/10.1016/j.chroma.2012.02.071
    21. Sarah C. Rutan, Joe M. Davis, Peter W. Carr. Fractional coverage metrics based on ecological home range for calculation of the effective peak capacity in comprehensive two-dimensional separations. Journal of Chromatography A 2012, 1255 , 267-276. https://doi.org/10.1016/j.chroma.2011.12.061
    22. Paola Donato, Francesco Cacciola, Peter Quinto Tranchida, Paola Dugo, Luigi Mondello. Mass spectrometry detection in comprehensive liquid chromatography: Basic concepts, instrumental aspects, applications and trends. Mass Spectrometry Reviews 2012, 31 (5) , 523-559. https://doi.org/10.1002/mas.20353
    23. Roman Dück, Hannah Sonderfeld, Oliver J. Schmitz. A simple method for the determination of peak distribution in comprehensive two-dimensional liquid chromatography. Journal of Chromatography A 2012, 1246 , 69-75. https://doi.org/10.1016/j.chroma.2012.02.038
    24. Dominique J.D. Vanhoutte, Gabriel Vivó-Truyols, Peter J. Schoenmakers. Pareto-optimality study into the comparison of the separation potential of comprehensive two-dimensional liquid chromatography in the column and spatial modes. Journal of Chromatography A 2012, 1235 , 39-48. https://doi.org/10.1016/j.chroma.2012.01.059
    25. P. Donato, F. Cacciola, L. Mondello, P. Dugo. Comprehensive chromatographic separations in proteomics. Journal of Chromatography A 2011, 1218 (49) , 8777-8790. https://doi.org/10.1016/j.chroma.2011.05.070
    26. Zhong-Da Zeng, Helmut M. Hugel, Philip J. Marriott. Chemometrics in comprehensive multidimensional separations. Analytical and Bioanalytical Chemistry 2011, 401 (8) , 2373-2386. https://doi.org/10.1007/s00216-011-5139-4
    27. Dominique J.D. Vanhoutte, Sebastiaan Eeltink, Wim Th. Kok, Peter J. Schoenmakers. Construction and initial evaluation of an apparatus for spatial comprehensive two-dimensional liquid-phase separations. Analytica Chimica Acta 2011, 701 (1) , 92-97. https://doi.org/10.1016/j.aca.2011.06.004
    28. Isabelle François, Koen Sandra, Pat Sandra. History, Evolution, and Optimization Aspects of Comprehensive Two‐Dimensional Liquid Chromatography. 2011, 281-330. https://doi.org/10.1002/9781118003466.ch8
    29. Paola Dugo, Luigi Mondello, Francesco Cacciola, Paola Donato. Comprehensive Two‐Dimensional Liquid Chromatography Applications. 2011, 391-427. https://doi.org/10.1002/9781118003466.ch10
    30. Mingxia Gao, Dawei Qi, Peng Zhang, Chunhui Deng, Xiangmin Zhang. Development of multidimensional liquid chromatography and application in proteomic analysis. Expert Review of Proteomics 2010, 7 (5) , 665-678. https://doi.org/10.1586/epr.10.49
    31. Jacob N. Fairchild, Matthew J. Walworth, Krisztián Horváth, Georges Guiochon. Correlation between peak capacity and protein sequence coverage in proteomics analysis by liquid chromatography-mass spectrometry/mass spectrometry. Journal of Chromatography A 2010, 1217 (29) , 4779-4783. https://doi.org/10.1016/j.chroma.2010.05.015
    32. Isabelle François, Alberto dos Santos Pereira, Pat Sandra. Considerations on comprehensive and off‐line supercritical fluid chromatography×reversed‐phase liquid chromatography for the analysis of triacylglycerols in fish oil. Journal of Separation Science 2010, 33 (10) , 1504-1512. https://doi.org/10.1002/jssc.201000044
    33. Luigi Mondello, Paola Donato, Francesco Cacciola, Chiara Fanali, Paola Dugo. RP‐LC×RP‐LC analysis of a tryptic digest using a combination of totally porous and partially porous stationary phases. Journal of Separation Science 2010, 33 (10) , 1454-1461. https://doi.org/10.1002/jssc.200900816
    34. Marek Noga, Anna Drabik. Wielowymiarowe techniki separacji połączone ze spektrometrią mas. 2010https://doi.org/10.31338/uw.9788323533399.pp.171-184
    35. Filippo Bedani, Wim Th. Kok, Hans-Gerd Janssen. Optimal gradient operation in comprehensive liquid chromatography×liquid chromatography systems with limited orthogonality. Analytica Chimica Acta 2009, 654 (1) , 77-84. https://doi.org/10.1016/j.aca.2009.06.042
    36. Krisztián Horváth, Jacob N. Fairchild, Georges Guiochon. Detection issues in two-dimensional on-line chromatography. Journal of Chromatography A 2009, 1216 (45) , 7785-7792. https://doi.org/10.1016/j.chroma.2009.09.016
    37. Jana Krenkova, Andrea Gargano, Nathan A. Lacher, Jeffrey M. Schneiderheinze, Frantisek Svec. High binding capacity surface grafted monolithic columns for cation exchange chromatography of proteins and peptides. Journal of Chromatography A 2009, 1216 (40) , 6824-6830. https://doi.org/10.1016/j.chroma.2009.08.031
    38. Isabelle François, Koen Sandra, Pat Sandra. Comprehensive liquid chromatography: Fundamental aspects and practical considerations—A review. Analytica Chimica Acta 2009, 641 (1-2) , 14-31. https://doi.org/10.1016/j.aca.2009.03.041
    39. Deirdre Cabooter, François Lestremau, André de Villiers, Ken Broeckhoven, Frédéric Lynen, Pat Sandra, Gert Desmet. Investigation of the validity of the kinetic plot method to predict the performance of coupled column systems operated at very high pressures under different thermal conditions. Journal of Chromatography A 2009, 1216 (18) , 3895-3903. https://doi.org/10.1016/j.chroma.2009.02.079
    40. Isabelle François, Deirdre Cabooter, Koen Sandra, Frédéric Lynen, Gert Desmet, Pat Sandra. Tryptic digest analysis by comprehensive reversed phase×two reversed phase liquid chromatography (RP‐LC×2RP‐LC) at different pH's. Journal of Separation Science 2009, 32 (8) , 1137-1144. https://doi.org/10.1002/jssc.200800578
    41. Krisztián Horváth, Jacob Fairchild, Georges Guiochon. Optimization strategies for off-line two-dimensional liquid chromatography. Journal of Chromatography A 2009, 1216 (12) , 2511-2518. https://doi.org/10.1016/j.chroma.2009.01.064
    42. Jacob N. Fairchild, Krisztián Horváth, Georges Guiochon. Approaches to comprehensive multidimensional liquid chromatography systems. Journal of Chromatography A 2009, 1216 (9) , 1363-1371. https://doi.org/10.1016/j.chroma.2008.12.073
    43. Yanming Liu, Zhimou Guo, Yu Jin, Xingya Xue, Qing Xu, Feifang Zhang, Xinmiao Liang. “Click oligo(ethylene glycol)”: An excellent orthogonal stationary phase to C18 for two-dimensional reversed-phase/reversed-phase liquid chromatography. Journal of Chromatography A 2008, 1206 (2) , 153-159. https://doi.org/10.1016/j.chroma.2008.08.013

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    You’ve supercharged your research process with ACS and Mendeley!

    STEP 1:
    Click to create an ACS ID

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    MENDELEY PAIRING EXPIRED
    Your Mendeley pairing has expired. Please reconnect