ACS Publications. Most Trusted. Most Cited. Most Read
My Activity
CONTENT TYPES

Figure 1Loading Img

Liquid–Liquid Equilibria of the Ternary Systems Undecane + 1,4-Diethylbenzene + Tetrahydrothiophene 1,1-Dioxide and Tridecane + 1,4-Diethylbenzene + Tetrahydrothiophene 1,1-Dioxide at T = (323.15, 348.15, and 373.15) K

View Author Information
Department of Environmental Engineering, Kun Shan University, Tainan 71003, Taiwan
Cite this: J. Chem. Eng. Data 2011, 56, 12, 4486–4490
Publication Date (Web):July 1, 2011
https://doi.org/10.1021/je200465z
Copyright © 2011 American Chemical Society

    Article Views

    142

    Altmetric

    -

    Citations

    -
    LEARN ABOUT THESE METRICS
    Read OnlinePDF (877 KB)

    Abstract

    Equilibrium tie-line data have been determined at 323.15 K, 348.15 K, and 373.15 K for the liquid–liquid equilibria (LLE) of the ternary systems undecane + 1,4-diethylbenzene + tetrahydrothiophene 1,1-dioxide and tridecane + 1,4-diethylbenzene + tetrahydrothiophene 1,1-dioxide. The relative mutual solubility of 1,4-diethylbenzene is higher in undecane + tetrahydrothiophene 1,1-dioxide than in tridecane + tetrahydrothiophene 1,1-dioxide mixture. The tie-line data were correlated with the universal quasichemical (UNIQUAC) and nonrandom two-liquid (NRTL) models. The calculated values based on the UNIQUAC model were found to be better than those based on the NRTL model; the average root-mean-square deviation between the phase composition obtained from the experiment and that from the calculation was 0.3788 for UNIQUAC compared to 0.4459 for NRTL. The values of selectivity and distribution coefficients were derived from the equilibrium data.

    Cited By

    This article has not yet been cited by other publications.

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    You’ve supercharged your research process with ACS and Mendeley!

    STEP 1:
    Click to create an ACS ID

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    MENDELEY PAIRING EXPIRED
    Your Mendeley pairing has expired. Please reconnect