ACS Publications. Most Trusted. Most Cited. Most Read
My Activity
CONTENT TYPES

Figure 1Loading Img

Liquid–Liquid Equilibria for the Ternary System Methyl Isobutyl Ketone + m-Benzenediol + Water

View Author Information
Faculty of Chemical Engineering & Light Industry, Guangdong University of Technology, Guangzhou 510006, P. R. China
School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640, P. R. China
*Email: [email protected]. Phone: 86-020-39322231. Fax: 86-020-39322231.
Cite this: J. Chem. Eng. Data 2014, 59, 11, 3324–3328
Publication Date (Web):September 18, 2014
https://doi.org/10.1021/je5003048
Copyright © 2014 American Chemical Society

    Article Views

    230

    Altmetric

    -

    Citations

    LEARN ABOUT THESE METRICS
    Read OnlinePDF (927 KB)

    Abstract

    Abstract Image

    Liquid–liquid equilibria data for the ternary system methyl isobutyl ketone + m-benzenediol + water were measured at temperatures of (298.15, 308.15, and 318.15) K and atmosphere pressure. The reliability of the experimental tie-line data was verified by the Hand and Bachman equations. The experimental data were correlated with the nonrandom two-liquid (NRTL) and universal quasichemical (UNIQUAC) models. The binary interaction parameters of these two models were reported. Both models correlated the experimental data successfully.

    Cited By

    This article is cited by 19 publications.

    1. Mark Mayevskiy, Anastasia Frolkova, Alla Frolkova. Separation and Purification of Methyl Isobutyl Ketone from Acetone + Isopropanol + Water + Methyl Isobutyl Ketone + Methyl Isobutyl Carbinol + Diisobutyl Ketone Mixture. ACS Omega 2020, 5 (39) , 25365-25370. https://doi.org/10.1021/acsomega.0c03718
    2. Nassima Lami, Abdelkrim Merzougui, Hasan Uslu. Measurement and Correlational Study of Phase Equilibria in Aqueous Solutions of N,N-Dimethylacetamide with 1-Pentanol and 1-Hexanol at 298.15 and 308.15 K. Journal of Chemical & Engineering Data 2020, 65 (6) , 2947-2956. https://doi.org/10.1021/acs.jced.9b01029
    3. Meiling Jiang, Yun Chen, Shuai Shen. Liquid–Liquid Equilibria for Octan-2-one + Dihydroxybenzene + Water at Different Temperatures: Experimental Data and Thermodynamic Modeling. Journal of Chemical & Engineering Data 2019, 64 (10) , 4454-4464. https://doi.org/10.1021/acs.jced.9b00506
    4. Yinshuang Zhang, Bokun Chen, Siyu Yang. Liquid–Liquid Equilibrium for the Ternary Systems (Methyl Isobutyl Ketone + Quinoline or Isoquinoline + Water) at 298.15, 318.15, and 338.15 K. Journal of Chemical & Engineering Data 2018, 63 (8) , 2758-2765. https://doi.org/10.1021/acs.jced.8b00096
    5. Nikolaos Montesantos, Matteo Chirullo, Marco Maschietti. Liquid–Liquid Equilibrium of Water + 2-Methoxyphenol + Methyl Isobutyl Ketone and Water + 1,2-Benzenediol + Methyl Isobutyl Ketone at 303.15 K and 328.15 K. Journal of Chemical & Engineering Data 2018, 63 (3) , 712-722. https://doi.org/10.1021/acs.jced.7b00887
    6. Hai Liu, Xuemin Yu, Peng Cui, Bing Jia, Yingmin Yu, and Qingsong Li . Liquid–Liquid Equilibria for the Ternary Systems Water + Cyclohexanol + Methyl Isobutyl Carbinol and Water + Cyclohexanol + Methyl Isobutyl Ketone at Different Temperatures. Journal of Chemical & Engineering Data 2018, 63 (1) , 95-101. https://doi.org/10.1021/acs.jced.7b00683
    7. Bing Jia, Kun Xin, Xiaoxiao Bian, Chuanfu Zhu, Yingmin Yu, and Qingsong Li . Liquid–Liquid Equilibria for the Extraction of Chloropropanols from 1,2-Dichloropropane Using Water or 1,4-Butylene Glycol. Journal of Chemical & Engineering Data 2017, 62 (3) , 1130-1134. https://doi.org/10.1021/acs.jced.6b00976
    8. Yicong Zhao, Song Lin, Hongyue Guo, Houchun Yan, Mai Han, Qingsong Li. Ternary (Liquid + Liquid) Equilibrium Experiment and Thermodynamic Modeling for Isoamyl Alcohol + o-Cresol + Water at 298.2, 308.2 and 318.2 K under 101.3 kPa. Journal of Solution Chemistry 2022, 51 (2) , 209-223. https://doi.org/10.1007/s10953-022-01140-8
    9. Shihua Dong, Bing Jia, Xiubin Chen, Xiaobo Jiang. Liquid–Liquid Equilibrium for Ternary System of Water + 2-Methyl-3-buten-2-ol + (Methyl tert-butyl ether/Butyl acetate/4-Methyl-2-pentanone/2-Ethyl-1-hexanol) at 308.2 K. Journal of Solution Chemistry 2021, 50 (4) , 544-557. https://doi.org/10.1007/s10953-021-01075-6
    10. Ran Xu, Yue-Hong Zhao, Qing-Zhen Han, Peng-Ge Ning, Hong-Bin Cao, Hao Wen. Computer-aided blended extractant design and screening for co-extracting phenolic, polycyclic aromatic hydrocarbons and nitrogen heterocyclic compounds pollutants from coal chemical wastewater. Journal of Cleaner Production 2020, 277 , 122334. https://doi.org/10.1016/j.jclepro.2020.122334
    11. A. V. Frolkova, M. A. Mayevskii, A. K. Frolkova, D. B. Pletnev. Developing Energy-Efficient Technologies for Obtaining Organic Substances Based on a Comprehensive Study of the Reaction and Separation Constituents. Theoretical Foundations of Chemical Engineering 2020, 54 (6) , 1215-1222. https://doi.org/10.1134/S0040579520060159
    12. Qingsong Li, Wenyang Fan, Houchun Yan, Xin Huang, Lili Zhang, Zhanhua Ma. Experimental determination and modeling of liquid-liquid equilibrium for water + diethoxymethane + methyl tert-butyl ether (or methyl isobutyl ketone) at 298.15, 308.15, and 318.15 K. Fluid Phase Equilibria 2020, 505 , 112353. https://doi.org/10.1016/j.fluid.2019.112353
    13. Yun Chen, Shuai Shen, Meiling Jiang, Youchang Wang. Experimental result and data correlation of liquid-liquid equilibrium for methyl isopropyl ketone + o, m, p-dihydroxybenzene + water at 333.15 K, 343.15 K and 353.15 K. The Journal of Chemical Thermodynamics 2019, 129 , 44-54. https://doi.org/10.1016/j.jct.2018.08.041
    14. Chao Guo, Yangtong Tan, Siyu Yang, Yu Qian. Development of phenols recovery process with novel solvent methyl propyl ketone for extracting dihydric phenols from coal gasification wastewater. Journal of Cleaner Production 2018, 198 , 1632-1640. https://doi.org/10.1016/j.jclepro.2018.07.161
    15. Qingsong Li, Bing Jia, Liping Wang, Mengmeng Yan, Hai Liu, Yingmin Yu. Liquid-liquid equilibrium for ternary systems of water + 2,2,3,3-tetrafluoro-1-propanol + isopropyl ether/tert-butyl methyl ether at 298.2, 308.2 K. The Journal of Chemical Thermodynamics 2018, 124 , 32-37. https://doi.org/10.1016/j.jct.2018.04.006
    16. Yun Chen, Kangning Xiong, Shaoming Zhou, Huimin Wang, Libo Li. Liquid–Liquid Equilibrium of Ternary Systems of Methyl Isobutyl Ketone + o-Cresol + Water at 298.2, 313.2 and 323.2 K. Journal of Solution Chemistry 2017, 46 (12) , 2204-2213. https://doi.org/10.1007/s10953-017-0698-4
    17. Hengde Li, Li Wan, Guoqiang Chu, Wei Tan, Baoyu Liu, Yanlin Qin, Yuqing Feng, Dalei Sun, Yanxiong Fang. (Liquid+liquid) extraction of phenols from aqueous solutions with cineole. The Journal of Chemical Thermodynamics 2017, 107 , 95-103. https://doi.org/10.1016/j.jct.2016.12.018
    18. Yun Chen, Huimin Wang, Ran Lv, Libo Li. Liquid-liquid equilibrium for ternary systems, methyl isobutyl ketone + (catechol, resorcinol and hydroquinone) + water at 333.15 K, 343.15 K and 353.15 K. Fluid Phase Equilibria 2017, 433 , 206-211. https://doi.org/10.1016/j.fluid.2016.11.005
    19. Yun Chen, Ran Lv, Huimin Wang, Mochen Liao, Libo Li. Ternary liquid – Liquid equilibria for methyl isopropyl ketone + (resorcinol or hydroquinone) + water systems at different temperatures. Fluid Phase Equilibria 2016, 429 , 93-97. https://doi.org/10.1016/j.fluid.2016.08.040

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    Pair your accounts.

    Export articles to Mendeley

    Get article recommendations from ACS based on references in your Mendeley library.

    You’ve supercharged your research process with ACS and Mendeley!

    STEP 1:
    Click to create an ACS ID

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    Please note: If you switch to a different device, you may be asked to login again with only your ACS ID.

    MENDELEY PAIRING EXPIRED
    Your Mendeley pairing has expired. Please reconnect